  1. shokyfehNortel

    CS1000 PRI RAI Problem

    Dear all, I have a problem in RAI counter. I have DID route 67 with DCH 9, and Igot RAI, then the loop is oos. please find the below print out and advise. DAN DCH 9 CTYP MSDL DNUM 9 PORT 0 DES PRIB USR PRI DCHL 4 OTBF 32 PARM RS422 DTE DRAT 64KC CLOK EXT...
  2. shokyfehNortel

    CS1000M 5.5 Can't access to the terminal

    I have CS1000 M, with redundancy scenario, (two cores). when it was working on the first core, I couldn't access the PBX through the direct connection (via serial), I tried to switch cores, but It didn't work, so I restarted the whole PBX, the the core switched, and I can access the PBX, the I...
  3. shokyfehNortel

    BCM50 Release 6.0 Echo problem on analog trunks

    Thanks man, I searched but I didn't find it, if you can just upload it to any ftp site like mediafire, ... and send me the link to my email, or write it down here. and you can attached to email and send it to me if it's no big file (more than 10 Mbyte) my email is: abdu_sh_al@yahoo.com...
  4. shokyfehNortel

    CS1000 PRI DID

    Hey all, It works when I tried to enter 2181104, and it really transfered to the 3204, but I have two points to be discussed. 1- when the 3204 is busy, it directs go to the operator, where the hunt is disabled. 2- when I dialed from the 3204, the number changed to be 218113204, how can I make...
  5. shokyfehNortel

    BCM50 Release 6.0 Echo problem on analog trunks

    Thanks Guys, But I really searched in the BCM documentation, if you can just tell me the name, or give me the link it will be perfect
  6. shokyfehNortel

    CS1000 PRI DID

    Thanks all, I am sorry, but I don't know how to trace in LD96, However I did in LD80 on some set, and I got that the dialed number is like this: 0112181104, I'll try to put the whole number in IDC and get back with the results.
  7. shokyfehNortel

    CS1000 PRI DID

    Thanks all for your support, but I don't know how to trace in LD96, I enabled the msgi and msgo but no thing appears when I got a call on the DCH. Hoowever I trace a call il LD80 on a digital set, and I got the dialed number as 0112181104 please any advise. Thanks for all
  8. shokyfehNortel

    CS1000 PRI DID

    Thanks all for your support. I don't know how to trace the call from LD96, I enabled the msgi and msgo, and when I got call on this DCH no thing appears. but when I traced it to a Digital Set, I got that the dialed number is 0112181104 I hope you can advise me.
  9. shokyfehNortel

    M3904 Display Issues

    Yeah, dude. It is usually the display broken, I mean if you open the phone, you will find that the LCD is connected to the processor inside the phone through some kind of carbon, there is no wires, just contacts, and some of this carbons had been dryed. It happened a lot with the M3904, M3905...
  10. shokyfehNortel

    application starts at 0 or 1 ring

    In LD 15 chg the CFN0 in rdr block to 1 instead of 4 Hope it works
  11. shokyfehNortel

    Offering a "PepeDog" TNB Spreadsheet with IP Sets

    Sorry, but would you please explain more ...
  12. shokyfehNortel

    BCM50 Release 6.0 Echo problem on analog trunks

    Thanks guys, but if the mismatching in impedence is existed, how can I comeover it?
  13. shokyfehNortel

    CS1000 PRI DID

    Yes, I have already assign it to the rdb in idc item change to yes, and put the number. with the same result. it is going to the operator.
  14. shokyfehNortel

    CS1000 PRI DID

    Thanks bignose21, I tried to build the IDC but this what I got: REQ prt TYPE idc CUST 0 DCNO 0 DCNO 0 SDID NO IDGT CDGT 1 1 0 4 3 2 0 4 1 1 6 6 6 6 6 6 as you can see the digits is not close to gether. and when I try to call the number 2181104, or 2181166, I...
  15. shokyfehNortel

    BCM50 Release 6.0 Echo problem on analog trunks

    Dear All, I have a really problem, when I am talking form IP phone to external analog trunks, there is a lot of echo, but when talking from the digital sets, It's okay. I have BCM50 6.0, there is also no patches on avaya site, Avaya guys told me that they tried to log in to the peps page for...
  16. shokyfehNortel

    CS1000 PRI DID

    Hi all, I am still new to the PRI, but I have already configured a pri card NT5d97 and the D-CH, but I don't know how to do the mapping between the external numbers and my extension, it's like the telco gave me 21810XX, and the XX are a range from 00 to 99, I read about the IDC, but the IDC...