This is a Merdian option 11 running rlse 22 software, I am attempting to connect the old Meridian (shortly to be replaced by the Shoretel system) The customer is relocating and is migrating over a 6month period .
I tried to set up the connection between the systems as Q931 and also DPNSS but...
I have set up a DASS link going to a DASS to E1 converter box and then onward connection to a Shore Tel System. The link comes up and all the channels show idle but I cant access the route?
Any idea,s
Depends on type of Stand bye power supply system
If You are in UK it will be a 2008b power system if its 14 years old
How many Batteries in the cabinets and what are the Voltages
I always use Yuasa if 8 X 6v batts (3VB11 Equiv)
Or Chloride is 12V batts if its Mpower
I need to generate a MN for the Customer.
The only way I know is mains failure or take dass link down.
The power system alarm isnt wired to Meridian so that wont work
and the Network supplier is bad at contacting to bring up Dass link if that doesnt come up.
Any one know how ???
Hi all
Anyone know where the alarms are wired to on a Power system 2008B
or where I can find a diagram.
Only got a diagram fro a 2008k,
and what condition I will get when there is a power failure
Customer now has no Switchboards and requires alarms extending to a Honywell Alarm System in their security. Any ideas what I need to wire from System Monitor and what outputs I would expect.
Does anyone know what the max distant a Analogue Extn will work and how to set one to Long Line.
A long distant Memory makes me think its something to do with last 4 ports on a FALC card and CLS.