Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations IamaSherpa on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Sean5395

    Caller ID for Meridian Mail

    That worked! Thank you very much.
  2. Sean5395

    Caller ID for Meridian Mail

    A customer has an OPT11 Rls 22.8D and Meridian Mail Rls 13.11.12. They changed PRI providors and at cutover we had trouble getting caller id. After going back and forth with them they changed the protocol from NI2 to D100. Now caller id works on the sets but is not working for Meridian Mail when...
  3. Sean5395

    BCM 400 slow boot up after replacing the Base Function Tray

    It took about four hours but it finally failed. I ended up replacing the hard drives and restoring from backup. I am suspect of the power supply as the root of the problem.
  4. Sean5395

    BCM 400 slow boot up after replacing the Base Function Tray

    I had to replace the Base Function Tray on a BCM 400 4.0 with mirrored drives. Now i have hard drive activity but it hasn't come all the way up after three hours. I can see activity on the sereial port and it seems like it is progressing but it's taking forever. Has anybody seen this before? Any...
  5. Sean5395

    NEC Desktop Configuration Manager Default Password

    Never mind, found it when I took my head out of my ass.
  6. Sean5395

    NEC Desktop Configuration Manager Default Password

    I'm looking for the default password for NEC's Desktop Configuration Manager. Can't find it in the docs I have.
  7. Sean5395

    BCM50 cannot redirect SIP call to PRI

    I have a CS1K 7.5 that calls a BCM50 Rls 6.0 thru CDP to SIP trunks. That part works. If the user in the BCM forwards off site, calls to their DID forward ok but CDP calls from the CS1K on the SIP trunks don't. Using BCM monitor I see the call come in but never tries to go out the PRI. Is there...
  8. Sean5395

    Nortel Opt 11 4.50W Forwarding problem

    Thanks guys! I had tried the CFO/CFF but that didn't change any thing. All this time I thought you couldn't have a mailbox numbered same as an SDN. Maybe that carried over in my head from Meridian Mail. But that's what worked and the customer is happy... for now.
  9. Sean5395

    Nortel Opt 11 4.50W Forwarding problem

    I am trying to forward calls from X2302, which has a mailbox 2302, to an application (voice menu) in Callpilot. I've changed the FDN/Hunt to 5302, and built 5302 as a dummy ACD that NCFWs to Callpilot, and as a Phantom DN that DCFWs to Callpilot. Both ways keep the originally dialed DN info and...
  10. Sean5395

    MGC Password for <crtl>LDB or <crtl>OAM

    I've tried the admin2 password from prior to and after the upgrade (when the call server joins the sec domain the old passwords don't work and you build new users thru the signaling/primary security server) I've tried the nortel and root passwords and have built new level 2 users but still no...
  11. Sean5395

    BOGEN PCM200C PAGING SYSTEM ON CS1000E 5.0

    You may need to build it as a cot so it will pass dtmf.
  12. Sean5395

    MGC Password for <crtl>LDB or <crtl>OAM

    I'm upgrading a CS1000 to 7.0 with two new MGCs. They have the correct CLAN and TLAN info and get Registration granted on the call server. They get the correct loop and shelf, but one doesn't get the centralized software upgrade. If I "stat ucm sys" in load 117 they come back as unregistered. I...