hi bambdi
I checked my cdr output's. I dont have an Access Code printed in the cdr.
plaese check the settings in the rout data block below
CDR YES
INC YES
LAST NO
QREC NO
OAL YES
AIA NO
OAN YES
OPA YES
OPD NO
NDP EXC 0
CDRX NO
CCO NO
Regards armada500
Hi,
I have a problem with the new Media Gateway 1010 and the
MGU NTC314AAE6. The DIP Switch 1/8 is on.
On the MGU Card all FAN LED are flashing red and green.
The LED of Ring Generator is permanently red.
On the analog Card is no 48 DC, no Ring Tone, no Dial Tone.
Does anyone have an idea ...
Hello
Thanks to all.
Yesterday I started with the upgrade to C7J. I just made a few tests with some Phones and not all together. Now I have to wait, how it will behave.
best Regards
Rolf
Hello M1spezi
Hello qwebster
Thank you for your answer. I thought also for a newer FW, but no reference to a well-known error i found. The Pep' s i will update only if i find a Patch, which me exactly the problem solve.
Regards Rolf
Hello
I have a problem with a CS1K Rel 5. As soon as I media security enable, (CLS MSBT), boots the IP Phones (1120 & 1140) sporadically. The FW of the IP Phone is CE6. the Signaling server prints the following error message.
SET: 10.20.71.12 TN 104-00-01-03 Terminal offline
VTM...