Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cmanalyst

    Move or Copy - how to move users/DNs

    Thank you ALL for your suggestions AND patience. It's working now.
  2. cmanalyst

    Move or Copy - how to move users/DNs

    I am still not able to change the CPND. Same error code as before.... >ld 11 REQ: chg TYPE: 2616 TN 12 0 2 3 ECHG no DES 3NE055 DES AOM FDN TGAR LDN NCOS RNPG SSU SCPW SGRP CLS RCO HUNT LHK LNRS SCI PLEV AST IAPG MLWU_LANG DNDR KEY 0 scr 2900 1 HNT FNA MARP...
  3. cmanalyst

    Move or Copy - how to move users/DNs

    OK, I've stumbled along and made some progress. On the user's exsiting 2616 set, I assigned an open DN to it. Then built the I2002 and assigned to user's extension from the 2616 set. So far so good. The problem is that now I cannot set the CPND on either type set using ld 95 or ld 20. What am...
  4. cmanalyst

    SSC NTDK20 Card Question

    The LEDs are all in the front face plate. LEDs labeled 1 and 3 are unlit. 2 is steady Green; 4 is a steady Red. Is this what you were after?
  5. cmanalyst

    Move or Copy - how to move users/DNs

    Dear Gurus I am tasked with moving several users from their current cubes to new cubes and keep existing DNs. All of users currently have 2616 sets and are going to get I2002 sets in their new cubes. How can this move best be accomplished? in ld 20, do I use the MOV or the CPY command? Is...
  6. cmanalyst

    SSC NTDK20 Card Question

    On my SSC NTDK20JA card, one of the faceplate LEDs is RED, which according to my NTP indicates that the SSC is running a self-test. The only problem is that the LED has been RED for several days now (over a week). Should I be worried? Amad
  7. cmanalyst

    Calls not going to voicemail

    I set the values for FDN and HUNT to the voicemail extension and the problem is resloved. However, I am not certain which one (FDN or HUNT) fixed the problem.
  8. cmanalyst

    Calls not going to voicemail

    Here's the TNB: REQ: prt TYPE: tnb TN 252 0 4 29 DATE PAGE DES 2SE061 TN 252 0 04 29 VIRTUAL TYPE I2002 CDEN 8D CTYP XDLC CUST 0 NUID NHTN ZONE 001 FDN TGAR 1 LDN NO NCOS 7 SGRP 0 RNPG 0 SCI 0 SSU LNRS 32 XLST SCPW CLS CTD FBD WTA LPR MTD FNA HTA TDD HFA CRPD...
  9. cmanalyst

    Calls not going to voicemail

    I just set up a I2002 set. All seems to be working except that calls are not going to the Voice Mail box. The user has a CallPilot vm box. In CLS of service, I have MWA enabled. Is there some other CLS value to enable calls to go to VM?
  10. cmanalyst

    How to lookup license information

    Hi, Which load will display the number of licences in use or available licences? Basically I need to lookup the number of available IP licences and Call Pilot licences for my environment. TIA Amad.
  11. cmanalyst

    Remove TN

    Thank you ALL dearly! Everything is working as expected! Amad
  12. cmanalyst

    Remove TN

    Ok, after this: >ld 20 REQ: out TYPE: 2616 TN 12 0 9 8 I am now getting this SCH0805 message: Specified TN is Invalid. Is this normal? How am I suppsoed to re-use that TN? >ld 20 REQ: prt TYPE: tnb TN 12 0 9 8 DATE PAGE DES SCH0805
  13. cmanalyst

    Remove TN

    Hmm..almost seems too simple...will I be able to use that TN again for another user? W Will I need to do anything special to use that TN for another user? Sorry for my basic questions..but this is a huge learning curve for me. Thanks. Amad
  14. cmanalyst

    Remove TN

    Hi, Can someone please direct me on how to remove the second TN entry for this user? I used ld 20/Easy Change to add the 252 TN and it's working as expected. I need to remove the 012 TN. Please help. TN 012 0 09 08 V KEY 00 H MARP DES 2SE57 6 OCT 2009 (2616) >ld 20 REQ: prt TYPE...
  15. cmanalyst

    ld 20 copy command question

    Ok, I have to apologize for my lame brain. The DNs I was entering are in fact in use but there's no user assigned to those DNs. I was mistaken in thinking that because no user is assigned to them, the DNs would be available. Obviously thats not the case. Using an unused DN, I was able to...
  16. cmanalyst

    ld 20 copy syntax

    Sorry for posting this question in the Symposium forum. I've reposted it in the "Nortel: CS1000 (Meridian) systems Forum". Amad
  17. cmanalyst

    ld 20 copy command question

    Greetings. I am attempting to build a i2004 set using the syntax below. The DN I am providing is unused but the error code suggests that it's not a unique DN. I've tried several unused DNs but I am getting the same error code. What am I doing wrong? >ld 20 PT0000 REQ: cpy 1 TYPE: I2004 CFTN...
  18. cmanalyst

    ld 20 copy syntax

    Greetings. I am attempting to build a i2004 set using the syntax below. The DN I am providing is unused but the error code suggests that it's not a unique DN. I've tried several unused DNs but I am getting the same error code. What am I doing wrong? >ld 20 PT0000 REQ: cpy 1 TYPE: I2004 CFTN...
  19. cmanalyst

    IP2004 Move Question (newbie)

    Thank you to everyone who responded. I appreciate the help! Amad
  20. cmanalyst

    IP2004 Move Question (newbie)

    Hi John, Thank you for your quick response. If I understand you correctly (since all of the users are on the same network), all I need to do is to move their phone sets from their current office to their new one? Thats it?!

Part and Inventory Search

Back
Top