  1. Captain1911

    AUD 572 and AUD 519

    Hi, thanks a lot for your reply. I will try the sysload later on when we are retrieving a site into a new mgwy. Regards Captain 1911 :-)
  2. Captain1911

    Nortel 1150 in unable to register in our Main CS1000

    Hi. Try configuring 1150 in the main and branch. point MOTN and BUID in branch the same as in the main. it usualy works fine. :-)
  3. Captain1911

    AUD 572 and AUD 519

    Hi. I have CS1000e HA rls.7.5 latest loadware and dep lists. 2-3 times pr. hour i recieve AUD572 and 519 msg. Have anyone seen the same, and found a solution for it? :-) AUD572 1 : 0 0F00CF48 0F00CF4E AUD0572 Q I MPTR MLN This XMI message register has an invalid queue ID or link pointer. q...
  4. Captain1911

    Password reset on opt11C 25.15

    Ok, thanks. We are the vendor for this cusomer. (probably not worth a crap). And we also know how to retreive passwords on newer machines. but not on the old unsupported 25.15.
  5. Captain1911

    resetting used DAP on sip dect?

    Hi all!! I have a new Sip-dect sytem "SIPL" on CS100E rel.7. DAP configurator 4.2 installed on win xp etc. Problem: the used Dect Access Point dont show in the manager. Possible, due to old configuration (unknown) on the DAP. I am looking for a way to clear the dap and configure it on the new...
  6. Captain1911

    Password reset on opt11C 25.15

    Hi. Can anyone help? I am looking for a way to reset the admin password set by another distributor. ( Distributor cant remember the pasword. or the one they have, dont work) I know we can contact Nortel/Avaya tech suport, but i am looking for a cheaper way. Thanks in advance....
  7. Captain1911

    Transfer to a busy DN is not giving BUSY!!!!!

    Hi all, I have an old opt11C system with Release 25.15. I am facing the following issue: Unknown password. set by another distributor. (and they dont know) Due to upgrade i need to reset the password. Is there another posibility to reset it than contact Nortel (Avaya support? Thanks in advance....
  8. Captain1911

    C4027/70 dect handsets.

    Nortel techsuport have now finished the investigation, and it is not possible to upgrade without the Zip dect applications DAP manager and DAP. Not possible through TM manager. a RMA req is raised to replase all this handsets with new sets with a new fw rls. :-)
  9. Captain1911

    loss of data due to rdun = disabled

    The system has now been reprogrammed (lost data) edd, copied backup frm the "single" folder on the CF card. CPU`s are redundant: >ld 135 CCED000 .stat cpu cp 1 16 PASS -- ENBL TRUE REDUNDANT DISK STATE = REDUNDANT HEALTH = 24 VERSION = Jul 28 2005, 04:14:02 Side = 1, DRAM SIZE = 512 MBytes...
  10. Captain1911

    C4027/70 dect handsets.

    Hi. I have opened a case against Nortel tech support. I have at least 8-10 customers complaining now. both 4027 and 4070. recieved new fw. But still waiting for a way to load the new fw, A description is found in the sip-dect dics. but with use of DAP manager and DAP. All my complaining...
  11. Captain1911

    loss of data due to rdun = disabled

    Yes i agree, it explain the loss of data, but why was the redundance disabled? I dont see why several of our systems sudenly goes into this state. And i would ofcourse like a dual prosessor system to check for the latest backup on restart.
  12. Captain1911

    loss of data due to rdun = disabled

    Hi, Thanks for your reply. my system is a CPP2 and i dont believe the sync command is valid in this matter. >ld 137 CIOD000 .sync CIOD001 Invalid command The data base it recovers from was about 4 months old. so we lost some data but we kept a prt of the sets from ld 81. But, we have seen...
  13. Captain1911

    C4027/70 dect handsets.

    Hi. Some customers reports handsets turning them selves off. several times a day. Calls cut off using Nortel recomended bluetouth headset on 4070 handsets. Anyone with the same experience?
  14. Captain1911

    loss of data due to rdun = disabled

    Hi. I have some questions about rdun. I have a 4.50 1000M (61C) The system was with unknown reason showing "rdun = disabled" (edd LD 43) (Why?) Not knowing exactly for how long this status has been on we had a power down caused by a external main power fault, lasting a few hours. This of...