Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. 2600hz

    BCM50 CP Tone Modification

    Hi guys, I thought I would provide an update on how things are going on my end. After a preliminary check through the firmware file, I realised it won't be as simple as changing any 'frequency' setting bytes as I had previously thought, silly me. This is because the firmware file in essence...
  2. 2600hz

    BCM50 CP Tone Modification

    Thank you for clarifying that, I really do appreciate it, ucxguy. I can at least focus on the correct file now. [thumbsup2] There are 2 files which are used to configure the DSP and they are loaded when the Media Services Manager is run. One is a small 12 kilobyte configuration file and the...
  3. 2600hz

    BCM50 CP Tone Modification

    CoreTel is an executable so its contents does not change. When it is run, it goes through a number of function blocks. One of them looks at the MP number in NVRAM (I think) and based on that, starts the various threads with the relevant parameters. It is a fairly large file with hundreds of...
  4. 2600hz

    BCM50 CP Tone Modification

    Ok that makes things a little bit easier to track down I suppose and thanks for clarifying the “TN” abbreviation... "terminal" would have been my second guess. If you think of anything else that might help, I’d appreciate it. You make a good point and the parameters are exactly what I'd like...
  5. 2600hz

    BCM50 CP Tone Modification

    In my case, the Australia profile. I have US, Canadian and Australian VoIP trunks (I have family all over). Whilst the US/Canada tones are fine, the Australian ones are not (and never have been) correct. Aussie dial tone is 400+425 (not 400) and overflow/reorder is 425 at -19db & -29db...
  6. 2600hz

    Analog DID Trunk and no Dial Tone

    Hi dennislongnecker Is there a way to disable dial tone detection on the DMG1008? If not, and depending on how well your IT department is stocked, you might consider putting a small Asterisk box in between the DID lines and the DMG1008. If you know how to program an Asterisk dial plan it's...
  7. 2600hz

    BCM50 CP Tone Modification

    Hi guys, This is a really advanced technical question about the BCM50 back-end so maybe an ex-Nortel engineer or someone at UCx might know. I'm trying to locate the source of the CP (call progress) tones that are played to the extensions in the system. For various reasons I need to make...
  8. 2600hz

    BCM 450 Login Fails

    Firebird Scrambler is correct - if you're able to login via the web interface, which relies on the LAN port, then that's not it. Can you login via SSH and try the following command: netstat -pntlu >/tmp/output.txt and then post the result of that file? (It shouldn't be too big). If you...
  9. 2600hz

    BCM 450 Login Fails

    Just out of curiosity, are you able to connect using BCM Monitor? Armen K - IT Consultant/Programmer/Switch Tech http://github.com/armeniki/ Always take a backup! Always use a UPS! Never give up!
  10. 2600hz

    BCM50 R2 to R5 upgrade file

    All good thanks! I guess it was R1 that needed those BIOS updates... Armen K - IT Consultant/Programmer/Switch Tech http://github.com/armeniki/ Always take a backup! Always use a UPS! Never give up!
  11. 2600hz

    BCM50 R2 to R5 upgrade file

    Ok thanks, I'll try that out. Cheers, A Armen K - IT Consultant/Programmer/Switch Tech http://github.com/armeniki/ Always take a backup! Always use a UPS! Never give up!
  12. 2600hz

    BCM50 R2 to R5 upgrade file

    Hi guys, I'm desperately looking for a copy of the R2/R3 to R5 upgrade patch/software. I've got a BCM50 R2 which I'd like to upgrade to R5. I already have an R5 HDD but I believe I need to run an upgrade patch to update the BIOS and a few things before installing the R5 drive. I checked...
  13. 2600hz

    BCM 450 Login Fails

    Hey CalgaryJeff, how did you go with your login issue? Were you able to connect via SSH? Armen K - IT Consultant/Programmer/Switch Tech http://github.com/armeniki/ Always take a backup! Always use a UPS! Never give up!
  14. 2600hz

    Avaya KRS has gone

    Hi couttsie, Yes, this was announced a while ago so many people have moved on to newer technologies such as cloud-based IP service. However, there are a few projects underway at the moment to help people who own these units. Even though they're now obsolete and unsupported, there are plenty of...
  15. 2600hz

    Hello I need the schematic of powe

    Hi cheikhdtn, Are you replacing the existing unit? What is it that you're trying to accomplish? Page 8-5 gives you some info: Link 1. Always take a screen shot! 2. Always make a backup! 3. Always use a UPS! 4. Never give up!
  16. 2600hz

    Modems over SIP

    Hi OzzieGeorge, Yes, this forum has quieted down a lot since a few years ago! I'm also to blame since I haven't logged on here for a while!!! [neutral] The NBN is definitely annoying a lot of people with faxes, EFTPOS machines and security systems, but it is still possible. If you really...
  17. 2600hz

    Nortel BCM and Caller ID Name

    Update: I have been told that the 8 bytes between the 9F and 8B bytes in the caller name facility IE are just encoding bytes. I've done a test without them and still no luck. Instead I'm pretty sure there's something going on with the CCITT Display IE. Hopefully someone can chime in and shed...
  18. 2600hz

    BMC50 not accepting incomming calls

    How long does it go into the alerting stage? If it's just for a second that means the call has no where to go. This can be caused by a required entry being missing or being incorrect. Check your settings under Loops and Application DNs in EM... Also can you post a screen shot of your BCM...
  19. 2600hz

    BCM 400 4.0 down

    Are you able to log in to BCM Monitor? That will help show system vitals and other info.
  20. 2600hz

    Nortel BCM and Caller ID Name

    Oh just in case, I have also tried using the Facility IE to send the name and still no luck. But if this method works ok for you please let me know as well. Interestingly, I'm not sure what the 9 bytes I have put in the blue square are for either:

Part and Inventory Search

Back
Top