hi, working now but dont want continuous as it is just a message not moh. also disconnects within 2 seconds. any suggestions? thank you all and yes, john it is cold here!!
Hi and I appreciate your help. Here is what I have built.
DMOD
ROUT 70
DES RAN
TKTP COT
PRIV
SAT
RCLS
DTRK NO
ISDN NO
PTYP
AUTO
TIM000 10:00 21/11/2008 CPU 0
ICOG IAO
RANX
SRCH
TRMB
STEP
ACOD 8089
CLEN
CPP
TARG
BILN
SGRP
OABS
CNTL
DRNG
CDR YES
INC YES
LAST YES
QREC YSCH0600
QREC YES
OAL...
very cool and thank you. moh is already utilizing pair one off the universal trunk card. on the far end they already punched down directly as per the color code.
this is what i put in for rdb
ROUT 51
DES INTERALIA
TKTP RAN
NPID_TBL_NUM 0
RTYP DGT
GRD PLAY
REP 1
POST ATT
RANH
STRT DDL...
Hello, tonight I have to remotely configure an opt11 to an interalia. I have read all posts referring to this and still would appreciate some clarification.
I understand the following:
Pair 1 from trunk card goes to bix and cross connects to pair one on interalia. White from orange pair goes...
Hello, I am looking for an all round telco person in Calgary. It would be good to have Option 11, call pilot and/or mm. We are willing to train even if not an option 11'er (if the person has been in the industry for a while, preferably familiar with Nortel switches). Position includes numerous...
Hello, its been a while! I am at a new office and the opt 11 is being replaced by cs1000. Is there a way to do a history on tns to find out when the last time they were used. We are short on licenses so I need to take some out and records arent accurate. Any help is appreciated. :) ajk
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.