Hello,
We can send fax through DID (with the service provider) to any PSTN line with no problem. Also, we can receive fax from a GSM modem (in area where there is no land line, a sim card with fax/data feature is used with the GSM modem that gives a fax/telephone port) connected to a fax...
Hello everyone,
we have a nortel 81c system release 5.0. We have a problem with one of the rings (ring 1 is OFF now and ring 0 is driving FULL). Three months back we have a FIJI0037 error comming the system and they installed some patches, and increased the number of call registers to 20000. Two...
thanks,
we installed a clock controller in the 2nd cabinet 8 0 and created the cc in ld 73:
mgclk 4 0 2
pref 4 0 2
sref
mgclk 8 0 2
pref
sref
.
.
the status of ssck in ld 60
ssck 4 0
enbl
clock active
clock controller - locked to slot 2
pref - 2
sref -
ssck 8 0
enbl
clock controller - free run
I...
Hi,
I have two option 11c cabinets. the 1st has cppm & MGC plus 1 PRI with clock controller & D-channel. the 2nd cabinet only has 1 MGC and 1 PRI without clock controller. I am getting DTA301 error every 3 minutes that cause the loop to go down when the counter reaches 255.
Questions:
what is...
site A:
m3902
key 0 hot d 4 (site B)
so there is no extension to be reversed in site A
because KEY 0 HOT D 4 (SITE a EXT1) (SITE A EXT2)
is valid only within the same site only
but when tried KEY 0 HOT D 4 (SITE B EXT) (SITE A EXT)
for the tie didnot work
Hi everyone,
we have two option 11c connected together via E1 PRI (TIE).
we need to program a two-way hotline between the two sites.
we where successful to program a two way hotline within the same site extensions, however when we used the same logic for the TIE didnot work:
KEY 0 HOT D 4 (SITE...
hi everyone,
I am getting dta301 error message on nortel 81c pri that is connected to a remote option 11c through E1 link. the link was tested and found no errors, but still getting the error almost every 30 seconds. on that remote 11c i am getting dta300 error message. the stat of loop in ld 60...