Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Stefanq

    Frequent restart for DBC 420

    Hi, The system is TSW sp6 IPLU FW R3F(latest) DBC420 boot file version is R3L Application file is R7E configuration file is R7E Frequently the DBC 420 telephones are restarting.(at least twice a day) The site is a mix of dbc 420 and dbc42, and NO PROBLEMS WITH DBC422!!! did any one experience...
  2. Stefanq

    TSE-MDE over IP

    Daddy is the tool trace2strap available on the infochannel? If yes, then where I can find it there?
  3. Stefanq

    TSE-MDE over IP

    I'm sure that MD-EVO is sending unknown private. I will update my system to SP3 and back to you.
  4. Stefanq

    TSE-MDE over IP

    hello mundus, Numbertype 10 and 11 didn't work. I tried all number types but no success. In the trace I found a message said "cmAlias number type:Error" at both calling and called connected numbers what do you think?
  5. Stefanq

    TSE-MDE over IP

    Hello Daddy, I did number_conversion_initiate -numbertype 5 -conversiontype 1 -pre 451 -entry 2 -targetdest 3 but the same no conversion made at the TS side (transit). ts_about ====== MX-ONE Telephony System ====== Version: 3.1 SP1 build13 RPM Packages ============ Telephony...
  6. Stefanq

    TSE-MDE over IP

    Hello, Can you help in the scanario below: Three PBXs are connected over IP (MX-1 Telephony server 3.1SP1,2 MD-Evo systems). The two MD-Evo are calling each other through the TS as required by the customer for billing purposes. directory 6000 belongs to the TSE. directory 2000 belongs to the...
  7. Stefanq

    Singal trace in TSE

    Is there any tool could help us in intrepreting signal traces in TSE??
  8. Stefanq

    A-number conversion, PRE works not with 6 digits

    Is there any limitation on the number translation table?? for example, I have 2000 entries, Is there any limitations on the number of entries?
  9. Stefanq

    Singal trace in TSE

    Guys, I tried signal trace in MX TSE-3.1 , butI can't interpret the signals using signal trace intrepreter which came with SAM tool box.. Can you help, how can I do that Job?
  10. Stefanq

    Dispalyed number in internal calls

    Thanks daddy,, its okay this works fine. one more question on the same topic: Is it poosible to program 7 digits extension number ??Is there any patch for this solution?
  11. Stefanq

    Dispalyed number in internal calls

    Waiting the experts advice...
  12. Stefanq

    Dispalyed number in internal calls

    Hi, I have TSWSP5 running in a site... the extension series are 100&&999 They have also DID numbers with the range 0912100-0912199 DID and DOD works fine... for example extension 100 has DID 0912100 and DOD 0912100. extension 101 has DID 0912101 and DOD 0912101. My question if I call...
  13. Stefanq

    12 LIM system

    Many Thanks for the kind support.
  14. Stefanq

    12 LIM system

    I got that if I need to set up a system of more than11 then I have to add the lims >11 by using the Xlim disposition table. So if I have 20 lim system, I first install the 11 LIM system, then add the lims 12-20 one by one using the X-lim disposition table,and for sure editting the file for each...
  15. Stefanq

    12 LIM system

    Hello,,, I have 10 LIMs system (BC11) and will be upgraded to TSW(BC13) and will add two more lims. I used to upgrade system up to 10 LIMs but this is the first time to have 12 LIM system. Which LIm dispossition table should I use? Should I use the Xlim dispossition table?. But I never used the...