Couldn't find a battery with tabs on the positive and negective sides. Got a single AA battery holder from Radio Shack soldered the leads in the old battery position installed battery in holder and put in a metal spacer to make up the space of the shorter batt.
Battery corrected problem.
I will...
Couldn't find a battery with taps on the positive and negective sides. Got a single AA battery holder from Radio Shack soldered the leads in the old battery position installed battery in holder and put in a metal spacer to make up the space of the shorter batt.
Battery corrected problem.
I will...
Thanks Doktor,
I'm going to replace the battery this evening and will be posting the results,
Fortunately this is a small system and no voice mail.Can reprogram in a few minutes.
Thanks again,
Thanks for responding Doktor,
So it is the lithium battery soldered to the circuit board that needs to be replaced? Can this be replaced without taking out the circuit board?
I was told it could possibly be in a black module that has the default programming stored in it.
Hello,
I have a Vodavi P# 5000-00 that won't keep programing during a power failure. When power comes back on phone display shows DKTU 24-D GSPD.V2.0B. I was wondering if it could be the Tekcell Lithium battery SU-AA02 3.6V size 1/2 AA that could be bad? Check battery has no voltage. If so can...
Hello,
I have a Triad-S that won't keep programing during a power failure. When power comes back on phone display shows DKTU 24-D GSPD.V2.0B. I was wondering if it could be the Tekcell Lithium battery SU-AA02 3.6V size 1/2 AA that could be bad? Check battery has no voltage. If so can this be...
Hello,
I just inherited a Vodavi system to be reinstalled and programmed, not exactly sure which system this is (Triad-S,etc.) . KSU model number is 5000-00 with a expansion 5002-01 with 8 Inifinite IN9015-71 sets.
If anybody can tell me what system this is it would be greatly appreciated...
Hello,
I just inherited a Vodavi system to be reinstalled and programmed, not exactly sure which system this is (Triad-S,etc.) . KSU model number is 5000-00 with a expansion 5002-01 with 8 Inifinite IN9015-71 sets.
If anybody can tell me what system this is it would be greatly appreciated...
Hello All,
Sorry for the delay in posting a fix.
Finally got PEPS installed and this corrected the backup problem.
Thanks strmwalker for all your help and thanks for all that replied.
Good Morning,
Turning off windows update didn't cure the problem.
Let me know if there are other suggestions.
Thanks,
Below is a print of the alarm monitor.
Alarm Monitor
Time Stamp Event Code Severity Object ID Instance Description
Call treatment failed
(Cause:-1.Cmd:3.Call...
Thanks for replying Bk,
Just to make sure I'm in the correct area I went to the control panel- Automatic Windows Update-then deselected Keep my computer up to date.
This was checked and download updates automatically and notify me when they are ready to be installed was also selected.
Is that it??
Hello,
I have a SECC 4.02.06 that reboots every two weeks on Sunday night at 10:12pm. Sometimes the system will come back up by itself and have a elan connection to the switch the next time I'll have to reboot it again to get a connection.I read thread 959-1003108 about having reports scheduled...
Sorry,I haven't posted a fix yet. Still waiting on customer to decide to do the PEPS, doesn't want to take down the system for that long. They don't know if it's worth it when we can back it up manually everyday. This is in a hospital and they're using a application to answer the main number...
strmwalker & bombaytelecom ,
Thanks for the replies,
I've tried several different times and a couple of different types of backups during the day with no results.