Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. allisondk

    Need Help getting a system inventory

    So is there any reports I can add to matworx to give me just a listing of inventory on phones in use/active?
  2. allisondk

    Need Help getting a system inventory

    Guys, I am new to NEC PBX's, we have at our site a NEAX 2000 IPS Digital w/Softkeys and a NEAXMail AD-64 Voicemail system. I need to pull a complete inventory of Phones and numbers active in the system. I would like to know the port each phone is active on (analog) and also IP address for...
  3. allisondk

    NEC user manuals

    Ozzie, I would love to get a copy of the files you developed. Would it be possible to post them or send me a link> Thanks, Darren
  4. allisondk

    Dial tone from outside line

    Here is what I get. REQ prt TYPE cequ CEQU MPED 8D SUPL 000 004 008 012 016 032 036 040 044 048 064 068 072 V096 V100 TDS 000 CONF 029 030 031 062 094 095 DLOP NUM DCH FRM TMDI LCMT YALM T1TE TRSH TRK 01 00 ESF NO...
  5. allisondk

    Dial tone from outside line

    Understood, so what LD do I use to setup the Phantom Numbers? I just admin the system and ensure it runs, we have a contractor that is not answering their phone today so I am trying to setup one Phantom on my own to see how this works and how much trouble it will be to setup 20+ numbers. Is...
  6. allisondk

    NTP Sync Time on Meridian Option 11

    Okay, We have a Option 11 that does have a IP address that is used for OTM to communicate to the system. How would I setup a Time Sync to sync the time on the phone system to the computer clocks. I know users have suggested ProComm but we do not have that, I would use Putty or some method to...
  7. allisondk

    Dial tone from outside line

    Guy's as sad as this sounds, its not for him, its for all cell users so they can lower LD Cost (international). I think since we do not have the option we will probably pass on the option and find another creative way like phantom numbers. What load does Phantom DID's?
  8. allisondk

    Dial tone from outside line

    I am now getting a SCH0775 when I enter DIS into the Type area, what causes this?
  9. allisondk

    Dial tone from outside line

    Thank you for the response, it looks like DISA is the method we have to take due to needs of numerous numbers to be dialed. Is there any standard settings I should look for, like isid or ccba or ranr?
  10. allisondk

    Dial tone from outside line

    I know this is not proper procedure, but our CIO is asking to setup a DID number that can be accessed from the outside then punch in a code etc... and get a dial tone to make calls. Example... user calls 444-1234 and gets the PBX, then they dial 123456 or whatever and get a dialtone, at that...

Part and Inventory Search

Back
Top