    Keep having to restart program units TLP60 & SLP60

    Hi HIMDP I did do a additional route yesterday, I inherited this system, so I programmed my own route as I always have for Cisco, I move the circuit this morning, lets see if it will sort out the signalling. I agree the clearing signal has an issue, and as I said before, this started happening...
  2. GFDANNHAUSER

    Keep having to restart program units TLP60 & SLP60

    Morning guys HIMDP for you: <HIMDP:LIM=13&4&7; DIAGNOSTICS FROM OPERATING SYSTEM TIME DATE 08:12:35 19JUL13 DIAGNOSTICS FROM LIM 004, LAST HIREI: 14:52:00 18JUL13 TIME DATE ERROR CODE 05:47:35 19JUL13 H'10 EXECUTION TIMEOUT LOGICAL PROGRAM ERROR ADDRESS = 0201F91C ENTER...
  3. GFDANNHAUSER

    Keep having to restart program units TLP60 &amp; SLP60

    Hi HIMDP Will do as soon as it happens again. Br
  4. GFDANNHAUSER

    Keep having to restart program units TLP60 &amp; SLP60

    Thank you Satellite. Will give it a go.
  5. GFDANNHAUSER

    Keep having to restart program units TLP60 &amp; SLP60

    Hi HIMDP and Satellite its TSWsp03, will upgrade, its a 13 LIM system with remote LIMS. I keep getting alarm code 2, and that is when it happens. It seems the programs execution times out. This only started recently, we had a link down, and there was rerouting done on the routers, I suspect...
  6. GFDANNHAUSER

    Keep having to restart program units TLP60 &amp; SLP60

    <ROCAP:ROU=158; ROUTE CATEGORY DATA ROU SEL TRM SERV NODG DIST DISL TRAF SIG BCAP 158 7110000001000010 5 3110000001 0 30 128 00040414 511110120031 111111 END <RODAP:ROU=158; ROUTE DATA ROU TYPE VARC VARI VARO FILTER 158 SL60...
  7. GFDANNHAUSER

    Keep having to restart program units TLP60 &amp; SLP60

    Good day Anyone have some advise for me? We have a E1 circuits going to Cisco routers, and at least twice a day I must restart the program units, TLP60 & SLP60. the lines show Idle and Busy, and it is usually on the first and last 3 trunks. Best regards
  8. GFDANNHAUSER

    Changing from TLU75 to TLU83

    Problem solved, no worries.
  9. GFDANNHAUSER

    Changing from TLU75 to TLU83

    Hi everyone. I have a problem, I am replacing TLU75 cards with TLU83/1 cards for analogue trunks, but when I do the ROEQI to the TLU83, it says incorrect board type? Anybody had this problem before? Regrds
  10. GFDANNHAUSER

    Cdiv in MX-one

    Hi Tono Do a gespp:csp=all; and it will print the CDIV parameters, the use Alex to cross reference if the CDIV is set correctly. BR
  11. GFDANNHAUSER

    H323 &amp; SIP extension passw set on TSE v3

    Thank you very much guys, it works. Regards
  12. GFDANNHAUSER

    H323 &amp; SIP extension passw set on TSE v3

    Thank you Satellite, I am using V.3, and it should have passw to restrict login, still gives too many parameters entered. I will look at the license.
  13. GFDANNHAUSER

    H323 &amp; SIP extension passw set on TSE v3

    Good day I am running a Aastra TSE v3 When I do the ipexi:dir=****,passw="XXXX"; it comes back with too many parameters entered, if I do not put passw, then it executes, why wont it allow passw? Anyone had this issue before?
  14. GFDANNHAUSER

    CiL over Ethernet

    Hi Singhbrindisi Thank you, we are doing CIL on HDU and it saved ours skins a few times, thanx! RM Optimiser? I dont know it at all.
  15. GFDANNHAUSER

    DBC 425 02 restarting

    Daddy I will check the Cript as well, if you want me to pst a coppy let me know please. Best regrds
  16. GFDANNHAUSER

    DBC 425 02 restarting

    Hi Daddy Sorry for the late reply, no automatic gategeeper discovery.
  17. GFDANNHAUSER

    DBC 425 02 restarting

    Hi Has anyone ever experienced this? IPLU is used and the DBC425 02 phones restart simultaniously, but the DBC 425 01 phones stay up? The latest - Application R7E & BootRom R3L They use the power adapters supplied with them, so its not a PoE issue. On IPLU cards. Much appreciated George
  18. GFDANNHAUSER

    25 Pair Cat5e Backbone cable

    The reason for 25 pair is that you start duplicating amount of twists in the pairs, in a 25 pair cable no pair has the same amount of twists. I did this cabling before, and it used to be AT&T wiring, now I think Bell that manufactures it. It can be used for structured wiring using the AT&T...
  19. GFDANNHAUSER

    GJLSP

    Hi there Unplug the E1 cable from the the GJUL4 on LIM6, and the do a GJTSP:LIM=6; If it still shows free, the you might have a the incorrect E1 on the remote side, in other words layer one is up, because there is a loop on the spare E1's on the microwave link. You see Layer 1 up, but you are...