  1. kevin906

    Asterisk symbol is prefixing the caller ID on transit calls

    Moriendi--thank you. Hardest part was figuring out how to delete it.
  2. kevin906

    Asterisk symbol is prefixing the caller ID on transit calls

    *****PROBLEM SOLVED***** Took me a while to figure out how to eliminate the asterisk symbols This command does it: CHA-KNDEF:100,,,**********,0; H500: AMO KNDEF STARTED H06: PARAMETERS DPLN AND ADPLN HAVE NO EFFECT AS THE VIRTUAL DIALING PLAN FEATURE IS NOT ACTIVE. H02: NNO 100 CHANGED...
  3. kevin906

    Asterisk symbol is prefixing the caller ID on transit calls

    The * is being inserted due to the KNDEF table I changed the values of the field ISDNLC to ***** with ISDNSK set as 5. The caller ID now shows *****713NXXXXXX on the outbound tandem call. Set it back to ISDNLC * with ISDNSK set to 0. Back to single asterisk. If I could just figure out how to...
  4. kevin906

    Asterisk symbol is prefixing the caller ID on transit calls

    Regen and tracs with diag flags does not offer any additional. thanks
  5. kevin906

    Asterisk symbol is prefixing the caller ID on transit calls

    System has PSS1V2 QSIG tieline from Cisco--these are the only trunks in and out of the system in question. User is routing a number offsite after hours to answering service. Caller ID inbound is OK. Caller ID outbound is prefixed with * character. The forwarding step is prefixing the caller ID...
  6. kevin906

    Multiple APE units fail on overnight sync---sometimes pass--common error seen on failures

    DIS-APS:,PSGL,Y*; H500: AMO APS STARTED ADINIT STARTED PROGRAM SYSTEM : Y0-EO0YC VERSION NUMBER : 10 CORRECTION VERSION NUMBER : 003 PART NUMBER : P30252N4604BH7601|V4 R4.1.76 PROGRAM SYSTEM WITH CODE SUBSYSTEMS INTERFACE VERSION: PROGRAM SYSTEM DOES NOT CONTAIN...
  7. kevin906

    Multiple APE units fail on overnight sync---sometimes pass--common error seen on failures

    Moriendi--Software release is Hipath V4.1.76, Unixware V4_R4.0.25 --no lectures on upgrading please, I have no way to get an upgrade. There is no single APE that ALWAYS succeeds, there is one that succeeds more than other ones do. No APEs on the same subnet, yes, that would be a great way to...
  8. kevin906

    Multiple APE units fail on overnight sync---sometimes pass--common error seen on failures

    Second text filehttps://files.engineering.com/getfile.aspx?folder=d33e551a-acab-4304-9c79-1e61faf8f6a7&file=APE_23_Interrupts.txt
  9. kevin906

    Multiple APE units fail on overnight sync---sometimes pass--common error seen on failures

    I don't want to go way out in the weeds on this issue but maybe if someone has seen it before and the fix wasn't overly involved... Multiple APE units for this site. V4.0 on old patches--no avenue for upgrades with no service contracts. Some nights APEs will sync up with no issue. Most nights...
  10. kevin906

    Siemens Hicom , Hipath /Unify - 24 * 7 online technical support

    Thanks hipath--will check that out and advise
  11. kevin906

    Siemens Hicom , Hipath /Unify - 24 * 7 online technical support

    hipath4K--- Trying to resolve the following problem. Hipath 4K--Release V4 R4.0.26 System has 8 local LTU shelves. System has 17 IPDA shelves. System had 4 APE units--all are offline for months. This site is to be decomm-ed in the next year or so and things get ignored and written off. Anyway...
  12. kevin906

    Landline ported to Boost Mobile without legal consent

    This is going to sound like a "story" but it's the truth. I have had the same landline in my home for 40+ years. Used for remote diags, etc. On or around May 8, 2020 somebody walked into a Boost Mobile shop or did some online shenanigans with my landline. They managed to get my landline number...
  13. kevin906

    STMI4 Reboot

    STMI4 Card rebooted and reloaded itself. I have not seen the associated error message before. Anyone else seen this and have any ideas? Not sure if the customer network was a contributor or if this card is suspect. The NCUI card on the same shelf showed no issues during this event and it's in...
  14. kevin906

    DSCR Errors when swapping CF Module

    Don, thanks for this. I have heard of this before. My support is to remote sites where I don't have much control over what goes in and what comes out. But I can pass this on to the customers I support and let them know. Maybe we can find a crate of these on Ebay.
  15. kevin906

    DSCR Errors when swapping CF Module

    Thanks for the reply---
  16. kevin906

    DSCR Errors when swapping CF Module

    We have some sites running V4.0 Software--yeah, I know. This problem has cropped up over the last few months. Customer likes to rotate the CF modules for backups. If they are just rotating an older CF issue does not seem to happen as often If they put in a fresh CF the system will not...
  17. kevin906

    Master CF won't load--attempting disk replacement with used disk

    I realize now this post makes little sense without any context. Short answer--in my position I service many flavors of Hipath/Hicom/Rolm heritage product. The parts that are available are not always refurbished or properly staged for field use. This is one of those occasions where a V3.0 Hipath...
  18. kevin906

    Master CF won't load--attempting disk replacement with used disk

    We are trying to rebuild a V3.0 system disk using a disk from a V5.0 system. This V5.0 disk was from a decommissioned system. Every time we try to boot from the HD-CF backup or Master CF V3.0 we see the message below about the wrong APS. It appears that the system is doing a stare/compare of the...
  19. kevin906

    Hipath 4000 V4 - PPP Dial configuration

    If you are dialing into the Hipath with PPP and you want to launch ComWin-- When the connection is established the remote system will have an IP addrees assigned. If you bring up the status of the connection this will be the Server IP address. You can also find this address in the WAN...
  20. kevin906

    Ring Cadence for QSIG/Cornet Calls

    Thanks for the replies--I need to get more information from the site and find out what they really want. I will run traces to investigate the setup messages coming from Cisco for both types of calls and proceed accordingly.