Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations TouchToneTommy on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cowboz

    External Alarm Test

    Appreciate the info and it worked great! Thanks
  2. cowboz

    External Alarm Test

    I have a MD110 BC11 SP15 I have an external light setup for class 4 alarms and want to test the functionality of this. Is there a cmd to send a test with out actually putting the system in a class 4 state? Thanks
  3. cowboz

    ACD Group Forwarding

    Parnum, Can you help with the cmds I am missing something I believe. I am trying to forward ACD grp 6623 to Dest code 6203. I have tried various Ad cmds but so far no success. Thanks for the help
  4. cowboz

    ACD Group Forwarding

    I have a BC 11 SP15 system I am trying to forward an ACD group to a DEST code. I am able to forward to other ACD groups as well as to an ext. I have tried setting up PELP on Ext to route to DEST code which works if you dial EXT but not if you forward the ACD group to Ext.
  5. cowboz

    Max Number External Dest codes

    I have a MD110 BC11 sp15 trying to find the maxinum external destination numbers allowed for the table. I have heard 2000 and also 5000. Trying to pin it down a little better so if any one knows the number I would appreciate the help. Best cowboz
  6. cowboz

    ACD Power Failure

    I have a ACD with 9.3 cm03 running this past weekend all the but 1 of the power switchs in the Switching cabinets turned off. The contollers did not go down and showed everyhting online. The Switching cabinets had no power on any cards. The circuits had no power surge as these are monitored by...
  7. cowboz

    Operator Workstation

    Any ideas on what may have caused it then encase i9t should happen again. I have noticed that I have an alarm the last few mornings of the Operator workstation loosing connection in the middle of the night which is unusual could this be connected? As you can tell I am not very familiar with...
  8. cowboz

    Operator Workstation

    Thanks parnum I was able to get it working after trying several things not sure which actually did it but I reset the equ and resync the system. I have DNA 5.3 by the way. Thanks again
  9. cowboz

    Operator Workstation

    I have a BC 11 SP15 with operator workstation before yesterday the keyword fields would always populate from fields in directory manager. Today it won't work I have checked all the keyword settings and the fields are checked to populate. Does anyone have any thoughts on what may be the cause?
  10. cowboz

    Speed Dial Feature Programming

    I have a BC11 system and trying to find the button to use when programming a "speed dial" from the extension to insert a pause in the dial string. Thanks in advance
  11. cowboz

    Integration to new IPT System

    Looking for any ideas on the best way to route calls from the BC11 sp15 to a new IPT system. This is going to be a slow rollout with around 5000 users/DID's. All calls will need to be routed via the Ericsson until the rollout is complete a year or two. My plan is add routes to the new system...
  12. cowboz

    BC 11 MD Disk Tool Errors

    The checksum test came back ok> Did the dump and still having the same error on MDDT. I am going to try to load it to a PC local at the site and see if possibly the WAN is the issue. Is there another option available to capture this information that anyone could recommend.
  13. cowboz

    BC 11 MD Disk Tool Errors

    I just started receiving these error messages when do a safety backup using MD Disk Tool on a BC 11 system. I have another system that I use the same client for and have not received the errors so I dont feel it is the MD Disk application. Any thoughts on how to proceed would be a great help...
  14. cowboz

    ACD 9.3 Traffic Info

    I am fairly new to the ACD what is the best way to get Traffic Usage Reports for incoming/outgoing T1's. Trying to determine if I have enough trunking to support some new Uniphi Connect users. Thanks "to hold or not to hold
  15. cowboz

    Individual Diversion

    Thanks parnum that was what I thought but wanted to confirm with an expert.
  16. cowboz

    Individual Diversion

    Individual Call Diversion on BC 11. When an extension is diverted to another and that extension does not answer should the call come back to the original extensions mailbox? Thats what we want to happen. Right now if the extension diverted to does not answer the call continues to ring and...
  17. cowboz

    Aspect Acivity Logs

    Does anyone have a link or idea of how I can get a readout of the activity codes and there meanings? Any help would be appreciated!
  18. cowboz

    Route Video Calls

    G3 Ver 12. Just setup 3 new Video Conference Units and I am trying to route all outbound calls over a specific SPrint PRI. I have them working now but only if I add all the called numbers into the ARS table. I would like to have all calls be routed over this circuit.
  19. cowboz

    Group Hunt Limit

    I have a BC11 system is there a maximum number of Hunt Groups a directory number can be assigned to? Thanks in advance
  20. cowboz

    Mics 4.1

    No your on the wrong forum MICS4.1 is a Norstar software release this is for Ericsson systems.

Part and Inventory Search

Back
Top