  1. idahomitel

    SX 200 ICP CFNA and xfer problems

    Went in through the phone, edited mailbox 0, gave it a new password, changed the extension back to 0, (had it going to ext 550 sub att because it has a generic greeting for the hotel. Problem mailbox is now deleted, bit when getting transferred to voice mail from a phone, I still get the name...
  2. idahomitel

    SX 200 ICP CFNA and xfer problems

    Checked, and no, as far as form 19 goes.
  3. idahomitel

    SX 200 ICP CFNA and xfer problems

    By done I mean checked. That's the way it was/is set. Form 19 nothing unusual, just set for LDN keys. I'll try again to listen to the "0" name. Seems like that wasn't an option, nor is deleting it and re-programming it.
  4. idahomitel

    Switched from Avaya IPO to Mibusiness solution. Call status software similar?

    Yes, there is a call staus in maintenance. By extension, trunk, software id, and show status all. Call shows ringing extension, then goes to idle after it forwards, doesn't show where it forwards to, however, but it forwards to operator mailbox, even though it says the GM's name.
  5. idahomitel

    SX 200 ICP CFNA and xfer problems

    Done. "0" is transfer only, and the extension is "0".
  6. idahomitel

    SX 200 ICP CFNA and xfer problems

    All overseas area codes are denied, I have the list. Calls are not going off-site, Dial "0" calls are getting the actual GM's mailbox name.
  7. idahomitel

    SX 200 ICP CFNA and xfer problems

    GM mailbox name has highjacked the operators default mailbox name, so upon cfna or dial "0", you get the GM name instead of "you are being transferred to the operator". Checked all fwding and re-routing.
  8. idahomitel

    SX 200 cfna to operator

    SX200 ICP general manager's recorded name for his mailbox has "highjacked" the default "The operator" when transferred to same. So when I reach the AA and dial "0", I get "you are being transferred to: "Adam Johnson". CFNA system wide is met with same.
  9. idahomitel

    5330 sets not ringing on co line keys

    SX 200 MX, no I haven't tried that. It's a remote site.
  10. idahomitel

    5330 sets not ringing on co line keys

    Have a couple 5330 sets that stopped ringing on CO Line keys, but will ring when someone calls it's extension. Also no blinking line key light either, so not volume.
  11. idahomitel

    AX Controller

    I have a controller with issues, won't boot up, just cycles. Suspect software problems. I have a boot disk I want to use to clean out the database. Does the boot disk go in slot 1 or 2, and should I leave the compact flash installed, and if so which slot?
  12. idahomitel

    SX-200 Lost MOSS

    Data base back-up, replace flash drive, replace T1 card, data base restore, everything came back up perfectly until... I looked at the T1 NIU and it was red! Replace cable all good! Thanks all! It was everything!
  13. idahomitel

    SX-200 Lost MOSS

    New controller, sys id button, resets and hangs. Pulled all station cards and just ran the console and ip sets. Resets, but comes back up wrong time and date that won't change. Suspect failing power supply.
  14. idahomitel

    SX-200 Lost MOSS

    Replaced sys id button on AX Controller and entered new MOSS and password. Everything is up and working, but every 2 minutes (reading logs) it cycles from old sys id installed to new sys id installed. Also Major Alarm, but all devices available in Alarm thresholds. Any advice?
  15. idahomitel

    SV8100 CFBNA

    Both good ideas. Thanks everyone for your help!
  16. idahomitel

    SV8100 CFBNA

    I am simply trying to accommodate the customer's request. It's a small business in Yellowstone Park that takes people on tours of the park. Since the park is closed, they have cut back staff, and would like the main number to forward to one of their other travel booking shops. It's ok that line...
  17. idahomitel

    SV8100 CFBNA

    Could I just take 101 out of the ring group to accomplish CF external and leave 102 and 103 in?
  18. idahomitel

    SV8100 CFBNA

    Thank you for responding. Ideally: CO1-ring 101 day, 101 night CO2-ring 102 day, 200 night CO3-ring 103 day and night CO 4 is not used. If I have 101, 102, and 103 in ring group 1,and set 101 to call forward no answer to the external number, will that work? I thought there was a conflict with...