    Restore problem Windows 2008

    You can try with W2K8 SP2. It seems to work better. But a certain number of files are still not restored (iis config, ...). To be continued !! I assume there is a problem between Networker and VSS. You can try with mapping path (ex: \\servername\c$) ant it works.
  2. bixente43

    Unknown error 21 when labelling a Tape

    Hi, Sorry for my late response. Microsoft has published an article about my problem (Article ID : 842411). The solution is to disable TEST UNIT READY request for tape devices. Now it works. Thanks a lot for your help.
  3. bixente43

    Unknown error 21 when labelling a Tape

    I've just found the reason of the problem. The W2K3 Server on which Networker 7.2 is installed sends messages (??) to the tapes and causes the errors on tapes. When i turn off the W2k3 server, I can label tapes and backup servers. When i turn on the server during a backup, errors are present...
  4. bixente43

    Unknown error 21 when labelling a Tape

    I have tested different things : - a new Emulex card (sale model) => NOK - Downgrade the FW 1.35.105 => NOK - Upgrading NW 6.1.4 to 7.2.1 => NOK There are 2 possibilities (because a 7.2.1 NW server connected to the SAN and the 2 tapes is working fine) : - the fiber link, - the...
  5. bixente43

    Unknown error 21 when labelling a Tape

    Information : The jbverify gives the following response : Summary report of jbverify ======= ====== == ======== Device Handle Blocksize Jukebox Drv No. Status ------------- --------- ------- ------- ------ \\.\Tape0 262144 STK9310E 1...
  6. bixente43

    Unknown error 21 when labelling a Tape

    Hi, I've just tried the tapeexer on a scratch tape. On the both drives, I have the same error : BasicTest: test begin rewinding `\\.\Tape1' ReadTapefile: ReadFile error unknown error 21 (0x15) write 0 failed, errno 5, Input/output error EotTest: test begin \\.\Tape1: open failed, unknown error...
  7. bixente43

    Unknown error 21 when labelling a Tape

    There are 2 servers but they are both on a SAN using the same drives and the same tapes (FC 9840A). Of course, when a server is on, the other if off (no DDS or something else...).
  8. bixente43

    Unknown error 21 when labelling a Tape

    I tried to erase the tape (mt -f \\.\Tape0 erase) and label it. No success... I don't have the read_a_block command (Windows and NW 6.1.4) and no other utility...
  9. bixente43

    Unknown error 21 when labelling a Tape

    the scanner -nv gives the following result : scanner: \\.\Tape0: opened for reading scanner: \\.\Tape0: rewinding scanner: Cannot set \\.\Tape0 block size: unknown error 21 (0x15) scanner: error, cannot set record size: block size ioctl failed scanner: scanning for valid records... scanner...
  10. bixente43

    Unknown error 21 when labelling a Tape

    It was what i thought. But STK has downgraded the FW. But the problem still occurs....
  11. bixente43

    Unknown error 21 when labelling a Tape

    Sorry, i have forgotten something : I have used the tapes on a Networker 7.2.1 server (Windows 2003). The drives were the same. I wanted to test this "new" version. I have labelled all the tapes (10) and i backed up servers succesfully. Then i stooped the 7.2.1 server and re used the tapes on...
  12. bixente43

    Unknown error 21 when labelling a Tape

    hi, Since a couple of days, it's impossible to label 9840 Tape on a Networker 6.1.4 server (windows 2000). We have the following error : "label write, unknown error 32" or "cannot set record size : block size ioctl failed" Sometimes a tape can be labelled. When i use it for a backup, it...