  1. qhguy

    two line function on a M3902 set

    Hi, Thanks for the options and the sharing folks, i will certainly try the CWT on one of the keys. Will share the results before i close the post. qh
  2. qhguy

    two line function on a M3902 set

    it is a single DN set, i however thought the CLS might have some options for second incoming calls. qh
  3. qhguy

    two line function on a M3902 set

    is there anyway to have another line for second incoming calls to a DN on an M3902 single line set? I have tried to use the ADL key for a DN key unsuccessfully. Thanks qh
  4. qhguy

    bug6071

    according to the NTPs: BUG6071 - Pointer to Call Register is not on a valid range.
  5. qhguy

    Trunk Cards

    i am aware of one other trunk type - FEX. the ntp may be of help, see the trunk load (may be LD14 or LD16).
  6. qhguy

    OPT 11C extension cabinet card lockout

    Hi pals, Thanks, but i will therefore need data on nortels standard fiber run. i will also be checking out the types of line Amps. I should also mention that i also have a fiber pair on the same cable used for data with no faults. qh
  7. qhguy

    OPT 11C extension cabinet card lockout

    My extension cabinet is equipped with a Fiber card and main cabinet with a Fiber D/Board. The distance between the cabinets is 620m and covered using a single mode fiber pair. quite randomly my analog card at the extension cabinet disables all the TNs. the only remedy for service restoration is...
  8. qhguy

    Opt 11C interconnecting Solution

    I have been seeing the astrisk referral a lot, hence i must lend the same consideration as given to other products. I would be grateful for opnions on the two approaches below: OPTION1 main site: Sipura3000 (connected to internal extension or DN and to site ethernet switch). Connection (main...
  9. qhguy

    Opt 11C interconnecting Solution

    The new site already has 3 analog trunks terminating there, hence asterick and direct IP phones are out.i will continue to explore options since i have about a month to do purchase docs.
  10. qhguy

    Opt 11C interconnecting Solution

    Hi Guys, i have checked out the Cisco, Nortel and Avaya solutions mentioned the specs. are good. i am also reviewing the mck extenders and teltone Officelink Solo, remote PBX extender products. The teltone solution seem cost effective but is second to a system from centrepoint talkswitch any...
  11. qhguy

    Opt 11C interconnecting Solution

    Thanks Guys,the remote site in question just need about 5 lines max. Hence the cheaper/est solution is prefered. grateful qhguy
  12. qhguy

    Opt 11C interconnecting Solution

    Most of our sites OPT 11C are interconnected using ITG -Trunks for internal VoIP Calls. I am tasked with finding a PBX solution other than Nortel for linking another site to our voice network. I am grateful for links and products that can be supported on the Nortel platform at half the cost of...
  13. qhguy

    Option 11 - Dialing 411 NOT!!

    Hi ALL, Our system is designed with OPT 11C at all sites and linked using ITG Trunks for internal calls. We would like to add another location to this VoIP service but are seeking a low cost soln (non OPT 11), i hereby beg suggestions on a direction.