  1. scs6264

    Cisco 1841 DSU/CSU WIC will not link to an Adtran TSU 120 DSX-1 Port

    It would appear that I have solved the problem at least in a sense. I tested with a new Cisco 1721 and found that I had the same issue. I then tried an Adtran Netvanta router and it worked just fine. When I looked closer at the IOS of the 1841 and the 1721 I noticed that they were both the...
  2. scs6264

    Cisco 1841 DSU/CSU WIC will not link to an Adtran TSU 120 DSX-1 Port

    Yes, The application is working just fine now. The application is exactly the same on 5 PPP circuits with the voice passing through the V.35 port and data passing through the DSX-1. I believe there is no issue with this setup as all traffic is data once it hits the adtran, the only differencr...
  3. scs6264

    Cisco 1841 DSU/CSU WIC will not link to an Adtran TSU 120 DSX-1 Port

    It would appear that I have solved the problem at least in a sense. I tested with a new Cisco 1721 and found that I had the same issue. I then tried an Adtran Netvanta router and it worked just fine. When I looked closer at the IOS of the 1841 and the 1721 I noticed that they were both the...
  4. scs6264

    Cisco 1841 DSU/CSU WIC will not link to an Adtran TSU 120 DSX-1 Port

    I have swapped WICs to no avail. I have also verified the adtran setup. The Adtran terminates the T-1 then I pass data channels off to the Cisco DSO's 1-16 esf b8zs 64k/channel. I have the exact same setup working on several other sites. The voice goes through the V-35 port due to the MCK...
  5. scs6264

    Cisco 1841 DSU/CSU WIC will not link to an Adtran TSU 120 DSX-1 Port

    Both WICs are WIC-1DSU-T1-V2. I don't believe that the WIC would be the trouble as the circuit comes up just fine when I connect directly to the T-1. Clocking on the router is set correctly; internal on one side, Line on the other. I have no T-1 alarms since the Adtran is connected to the T-1...
  6. scs6264

    Cisco 1841 DSU/CSU WIC will not link to an Adtran TSU 120 DSX-1 Port

    I am installing a Cisco 1841 router at two locations. These locations are connected via Point-to-point T1. I am using an Adtran TSU 120 with to fractionalize the DSO's so that I can pass Data traffic and connect a remote PBX gateway. I have programmed the DSX-1 port of the adtran for DSO's...
  7. scs6264

    Nortel 2430 Multiprotocol Router (passport)

    Help! Does anyone outthere have a configuration guide for the Nortel Passport 2430 Router. Having trouble programming it through the Site Manager and bcc. If there is a soft copy out there it can be sent to Shawn.c.smith@earthlink.net. Thanks for any help!!
  8. scs6264

    Nortel 2430 Multiprotocol Router

    Thanks You so much for this information HunryHouse!! I will get the site manager and proceed from there. Shawn
  9. scs6264

    Nortel 2430 Multiprotocol Router

    I appreciate your responses. HungryHouse, since I do not have Nortel Site Manager; do you know of any information for programming this router by command line. My e-mail address is Shawn.c.smith@sprint.com if you have any pertinant information. Thanks again!!
  10. scs6264

    Nortel 2430 Multiprotocol Router

    Hello, is there anyone that can provide information on bonding two t-1's together on a 2430 Multiprotocol Router. I have searched Nortels Website and can find no information. I have done this many times on Cisco equipment, just need some direction on The Nortel. Thanks in advance for any...