This is some info I have had from Panasonic
- Main Unit
KX-NSX series : Target CPU is used. (This vulnerability is not concerned. *1)
KX-NS series except KX-NS1000 : Target CPU is used. (This vulnerability is not concerned. *1)
KX-NS1000 : Target CPU is NOT used.
KX-TDE/NCP series : Target CPU...
I had a similar issue on a NS700 , 4 remote phones, 2 would work and 2 wouldn't, customer is using a basic netcomm router at the remote end, a re-boot of that router got all back up and running, but a higher spec'd router has been proposed to hopefully avoid this happening again
At the moment we seem to be having issues with Sip extensions and POTS trunks, just heading to a site now to change the codec priority from 729 to 722 on the phones
Just installed our 1st HTS 824 and have a couple of issues
POTS lines and I am getting 1 way speech on outgoing calls , from both the Keyphone and SLT's. A test phone across the telco trunks at demark is all good, speech on incoming and outgoing calls
I have a customer using a NS700, they have an off site office where I have 4 NT-551 phones
Recently they started having issues where there was no speech path when calling from NT-551 to NT-551 at the remote site, they can call other extensions physically connected to the NS700 and calls to...
Go to system/numbering plan/main
first check under the feature tab to see if any features are using the digit "3" as a code, (if it appears as a single entry, delete the number and apply)
Then open the extension tab and change the leading digit "1" to "30" then apply
Now your extensions should...
I will try Merbacs' suggestion, I have tried deleting buttons on individual phones, and swapping for another msg wait 6XX but the light comes back on when I program it back to 601, it only seems to be effecting 601
obtsystem
Screen goes blank (as if it is responding to call the destination, but nothing on screen
Merbac
I have tried that, still nothing , I have also manually turned light on ( even though it already is) and manually tried to cancel(message says light is off , but it is still on)
FTPMike
I...
Morning All
I have a NS700 and set up an overflow ffrom an ICD gp 601 to voicemail
I have the msg wait light appearing as a message light on 4 x IP keyphones and 1 x digital keyphone
The issue is that I cant get the MSG wait light to go out , It is continually lit on all 5 phones
I press the...
I would look at deleting the 1st 0 on your ddi table (back to 10 Digits)
another way to confirm that the string is not matching would be to change the operator extension to some other extension (maybe 212) make an inbound call , if it rings to 212 ten that would definitely point to a mis-match...
So if you ring the operator - Both phones ring?
If you ring ICD 601 - Both phones ring?
If you ring the ddi - Only 214 rings?
I think it is an issue with matching the amount of digits the provider is sending in ( Here , we can get anything from 3 to 10 digits depending on the Telco)