Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cclausen

    G3si Prompting Buffer Full

    You might want to try "change system features" and see if there is anything in the various pages for increasing the size. Chris
  2. cclausen

    Logon script

    I would use the xcopy or xcopy32 command. It has options to most of the common things. The /d option will copy the file only if it is newer. Chris
  3. cclausen

    LMhosts Misery!

    Do you have WINS settings netbios 048 set as tyoe 0x8 This should query the local first and then the remote. Chris
  4. cclausen

    DHCP won't give out any addresses

    Maybee the DHCP database is corrupt. Stop the service, nuke the database and restart the service. Who knows? Chris
  5. cclausen

    Problems trying to Map H:

    Sometime you need to put quotes (") around the command if it's in a script. Try putting quotes around the command line. Chris
  6. cclausen

    KIX32 Error...dropping @HOMEDIR

    You could try to use the /d (debug) option in the kix login script. It should help narrow down what is causing the problem. You will have to hit an enter key to step through the steps of your login script so I hope it's not to long. Chris
  7. cclausen

    DHCP

    I believe you can create a "superscope" to overcome this problem. It take pools of ip address and creates on big pool. Chris
  8. cclausen

    adding wins server

    Why don't you want to use WINS on the PDC?? Chris
  9. cclausen

    Multi-subnet NetBios

    If you have different subnets you will need to use WINS. Chris
  10. cclausen

    Logon script using if member

    The ifmember only works for NT/2000 machines. Win9x will not work using ifmember. I pounded my head against the PDC to get it to work for logon scripts, it didn't, but I did get a bruise! I went to kix32 and it worked great! You can get it at www.kixtart.org. Good luck!!! Chris
  11. cclausen

    DHCP / IP Conflicts on clients

    How long is the lease time for the IP address? If you have no issue with enough IP address' I would bump up the number. After 50% of the lease time has expired the client will check with the DHCP server to see if it's lease is still good. At 85% it will try to renew the lease again. It can...
  12. cclausen

    Computer Names

    Could you query the WINS database and get the names. It's an MDB file so it should be possible. Chris
  13. cclausen

    time of day call coverage

    Don't forget to make the TOD coverage path!!! Use the add cov time {x} (pick an unused TOD path) Chris
  14. cclausen

    DCS and VoFR

    Make sure the frad device is not playing with channel 24. It can't do anything to the D channel or it won't work. Also what type of PRI did you program in the Definity. A, B? Chris
  15. cclausen

    ARS Analysis table

    If the ars ana table points to a P1 as the route, then you are using partition tables not traditional routes. You can the do a disp partition {x} x being the number it showed in the ars route. Then display the partition route table to find the route it uses. Chris
  16. cclausen

    g3 power supplies... How do you convert to 220v?

    I do not believe a domestic MCC cabinet with the 631DA1 and 631DB1 power supplies can be converted to a GMCC cabinet. The 649A has a different wiring arrangement on the plugs that connect at the front of the cabinet. The MCC cabinet has one (1) -48V source on the plug and the GMCC has two (2)...
  17. cclausen

    Setting up 10-10-323 LD service

    What version of Definity are you on? If you are version R8.3 or higher use the list trace station {extension numbet} to check the ars. It will give you the detailed analysis of the dialed digits, patern match in the ars ana table, trunk group selected, AND more importantly the dialed digits...
  18. cclausen

    Dead Calls

    If you pass the call back from the Conversant using a converse data step, it looks like you are doing this, you can pass up to 20 digits (yes I know documentation refers to 16 digits) back to the switch. The receiving vector will now receive the digits via a converse data return. Assume the...
  19. cclausen

    G3si and ANI (caller ID)

    I assume you mean ANI? You would have to have ISDN PRI to get this information. I have several questions. If you have ISDN. Do the phones have displays. If they do, you will get ANI if it is sent. As of R8.4 the ISDN PRI meets the Bellcore specs and can now receive Name and Number. On the...
  20. cclausen

    G3si Prompting Buffer Full

    Need some more informaiton. The switch stores digits in a digit buffer. This normally associated with a collect in a vector. Are you using vectors on your system?

Part and Inventory Search

Back
Top