Yes it is running and Nortel has tested this to run on Windows 2003 BUT Microsoft does not support having the SOAPIS30.DLL on a Windows 20003 Server.
So if your running SWC 4.5 on a Windows 2003 Server, you are running a solution that Microsoft does not support. And who is bigger kid on the...
SWC 4.5 utilizes Web Servics that were written using the MS SOAP 3.0 Toolkit. The following MS Link http://support.microsoft.com/default.aspx?scid=kb;EN-US;811215 has stated that MS will not support SOAP 3.0 Server components on Windows 2003.
Guess what: SWC 4.5 installs the SOAPIS30.DLL on...
And to make matters even worse, the standby server needs to be re booted not once, not twice but three (yes three) times before it can start to take live calls. And this is nortels state of the art 5.0 standby option.. :-(
I think what takes so long is the running of the Replication Server Management Utility. And note that this 15 mins includes the time it takes to notice there is a problem, the time it takes to decide to fail over the Active SCCS server to the Standby SCCS server (its all of nothing on the SCCS...
I am wondering if anybody out there has had direct experience with the so called standby option of SCCS 5.0. In a failure situation with an Active SCCS Server, the standby SCCS server needs to have its IP Address/Host name set to the IP Address/Hostname of what was the Active SCCS Server...