Hi, been working with Avaya for couple of weeks with this, applied binary patch which seems to have stopped the lookups, 8.0.46. Avaya states problem exists all the way up through 8.1. Running trace logs for avaya so they can further analyze data on how the patch is working. At this time Avaya...
OK, so the line measures 52 Vdc when idle. After other party hangs up I get a drop to 6.6 vdc. The IP Office still won't drop the line. Going to upgrade to 8.1 and see if anything changes. Thanks for the help guys! -John
Thanks, I tried your sugestion but unfortunately it didn't work. I think the problem lies on the far end, they are sending a plain analog station over to the IP Office. I'm having them install an OPX card to send me the line with better supervision options. Thanks for your time, I hope I can...
Hi all, installed my first ip office. Its an ip office rls 8.0.44. A simple setup. 5 9508 phones and 4 loop start lines. I'm having a problem with disconnect on one of the loop start lines which is an OPX from a nearby office. After a call over it the line just remains offhook forever, tried...
Hello, I would not recommend that many phones on a Norstar, you will most likely start to run into problems with running that many ports on a system not truly designed to handle them. Might be time to upgrade to Nortel option 11 mini or 1 cabinet option 11c.