Hello Forum
Please help with this problem. I have a pure hp-ux 11.x environment with DP6.0.SAN ml5030 backup system.My problem is the backups all work fine , except when i need to restore the previous weeks data. When I kick off a restore request it request the tape numberxxx. When i insert...
hello there admin
Does anybody have a script to check which tapes were used in the latest backup and then send them to the inport to be taken offsite as well as request tapes when their offsite retention period is finished and they available to be reused.
thankls in advance...
hi NB Admins
Could i use the duplicate feature in NB6.0 for offsite and how best would this work ,need to get script together that checks the offsite pool and ejects the tapes to the inports adn emails admin of the tapes offsite ,any ideas would help
Hi Bob
I read about how one can input policy wide exclude lists on the server ,so all clients on that policy will use the ploicy exclude if you check $nbdir there is an includes file which is client wide so i was looking at a policy wide excludes list
Hello Admins
Please could you help !!! I need to setup policy wide exclude lists for windows clients on a unix server . i tried to put them in the $nbdir/db/class/policy /schedule and no joy. would the directories,files and wildcards be case specific on the server even thought the clients are...
thanks for the replies but there no automated procedure where on a weekly basis suspend the weekly tapes they get moved to the inport and removed till further requiredor until they expire ....and can be re-used ..
Hello NB Admin
Is there a way to eject the tapes from the library once the scheduled backup is done . what we trying to achieve is once all the clients have been backed up the tape should ejectfrom the drive and placed in the tray to be taken offiste.
How can this be achieved that on a daily...
hi thank you for your reply i have about 2tb all connected to a san arbitrated loop. locally i get very good speed but my nfs mounts just grind down to about 8mb/s whereas locally I get about 15mb/s. the server is well specked 4gb ram 2xcpu single pci lvd scsi nothing else on the chain
hello admins
I tried to install the l8 loader as per veritas instructions.After changing the st.conf file to show the new device and use veritas drivers. it is not seen even by the os ,sgscan show the device with target ???? instead /dev/rmt/0. once the sga andthe ultgruim 1,0x00 etc entries...
hi guys thanks for the updates and the picture is getting clearer now .Just one question when running topas or memory usage after the aplied changes to the memory tuning parameters , will I get less memory beig used?how will know the difference besides not being called by users of a slow...
4 procs 4gb mem vm stat shows :
System configuration: lcpu=4 mem=4096MB ent=2.00
kthr memory page faults cpu
----- ----------- ------------------------ ------------ -----------------------
r b avm fre re pi po fr sr cy in sy...
Thanks for this info, so what causes the server to start swapping when busy and high i/o on the database disk The memory stays at 99% and then we get page faults in and out. lsps -a shows useage at 99% as well. User affected being unable to access the server or when logged in its very slow...
Thanks for the quick reply
I mean with topas or nmon I have the like of 99.3% physical memory used. at times some page faults and paging as well ,diks idle cpu's are idle
Hello tek tips
I have a p5 series server aix 5L with database re db2 running but after db is shutdown memory still remains high.Does aix have a way of releasing physical memory back to the system are there setting i need to change