  1. joebocc

    BCM 450 fan Alarm

    thanks bditech do you know where i can download the patch from? i am still working with the networking section for a site setup for the bcm. they are holding back to make sure the system is working properly and not causing system slowdown with all the critical alarms. i now get at least 10 in a...
  2. joebocc

    BCM 450 fan Alarm

    I hope this is all you need. BCM5450 Serial #: LBNNTMEND8W37L Sys ID: NBCMMVJBJCHH BFT FRU PEC: NTC0313SYE6 BFT FRU CPC: N0172305 BMB TYPE: BASE MOTHER BOARD BMB SOFTWARE VER 1 BMB Serial #: LBNNTMEND8W37L BMB PCP PEC: NTC05100-03 BMBPEC CPC: N0164482 Software ver 9.0.1.01.480
  3. joebocc

    BCM 450 fan Alarm

    I'll check it out when I get back to work tomorrow, Thanks
  4. joebocc

    BCM 450 fan Alarm

    Having the same problem with my new 450 5.0 that I am getting ready to install. Do I need to send it back for repair or is there a patch.
  5. joebocc

    COS Passwords

    Thanks, thats pretty much what I decided needed to be done. I was hoping there was another way so I didnot have to program line pool access to all the phones. Thanks again BOCC
  6. joebocc

    COS Passwords

    I've done all that but unless I pre-assign a line to the phone, and set the restrictions, I can not get a line to use.
  7. joebocc

    COS Passwords

    I know how to make a COS password, but what I am not sure of is "Do I have to assign and restrict a line/line pool to all phones that the user of the COS password may use?" I have tried to use a phone with no lines/line pools assigned and all I get is "ACCESS DENIED". It seems to be a lot of...
  8. joebocc

    3 x 8 calling an ACD

    Thanks, that was it. I never thought to check that. You would think in this day and age that tone would be the default (-: I guess it was just too easy to over look. Once I got on site, I could hear it pulsing. Tks again Joe
  9. joebocc

    3 x 8 calling an ACD

    I have a 3 x 8 DS system installed and whenever I call to a location that is answered by an ACD I cannot enter ANY choices without the line disconnecting. This is a replacement for a system that went belly up and use to work. WHAT AM I MISSING?
  10. joebocc

    Ringer Volume blocking

    I have a user that has some, [noevil] workers that turn down the ringer to avoid calls. Is there a way to block this and still allow use of other features on their phone. [bigears] Joe Bocc
  11. joebocc

    SMDR6 Manual in PDF

    Any chance I can get a copy of the manual. I just came accross an smdr5 and hope to be able to connect and use it on a mics 5.0 system. My E-Mail is cn1329@coastalnet.com Tks Joe Bocc [hourglass]
  12. joebocc

    Message waiting, no message waiting indicator though..

    We just answered our own question we forced time and date 'static time' F#806 fixes the problem thank you very much for ur help!!!!! DOH!! [2thumbsup]
  13. joebocc

    Message waiting, no message waiting indicator though..

    7208 had messages in the Norstar Voicemail MBox(new messages), but the user had no indicator on the display..... We tried F981, password, option 8, option 6, at which point enable message indicator and times for display We tried F983 Mailbox admin set MBOX to MSG indicate yes We deleted...