  1. rakirong

    Webswitch 2000 Config

    ButtonIt, It seems the setup is okay but you are right you should have a NetManager that match w/ WS2000 version. Since you have WS2000 ver 3.0, your Net Manager must also be ver 3.X . But before doing anything else can you pls check your setting in the NetManager for H.323 extension & set it...
  2. rakirong

    Webswitch 2000 Config

    ButtonIt, There are lots of things to consider when setting up the WS2000 & Ip extension, pls list down the programming did so we can see. first thing is you check the subnet mask of WS2000 & IP Phone( it should have the same subnet mask to make it work). You cannot use the latest WS2000...
  3. rakirong

    BACK PLANE SPEED

    Pls check which one you need; 1)MD110 processor is running at 20 MHz & it has two processors in the LPU board. The main processor M68030 for Plex program execution & the assisting processor M68302 which handles communication. 2)The LSU board has 2MB/s signalling channel in R8 which is speeded up...
  4. rakirong

    False Busy Trunks on TL 11

    iS THIS THE TYPE OF FAULTS YOU ARE GETTING WHEN YOU DO ALLOP AFTER THE CALLS? RDATE RTIME 21JAN03 11:33:37 260 FAULT ON LINE TO INTERWORKING PABX OR PUBLIC EXCHANGE DATE TIME ALP NOIF UNIT EQU BRDID INF1 INF2 21JAN03 11:33:37 12 28 TLP11 002-2-10-02...
  5. rakirong

    False Busy Trunks on TL 11

    Do you have a voice mail system in your pabx?Where is the destination of your incoming calls?& lastly is DISA feature activated in your system?
  6. rakirong

    False Busy Trunks on TL 11

    Does this problem happen on incoming or outgoing calls only? Or it is happening in both cases?
  7. rakirong

    False Busy Trunks on TL 11

    post your route data so we can see(RODAP),the programming might be wrong.
  8. rakirong

    How to enable time & date on a DT570 DECT handset

    Your ELU31 board must have the latest revision to make it works.