I know you resolved this by defaulting but I had this same issue and wanted to share my findings.
I found that someone enabled block forwarding in the user rights the users were a member of, This will cause the issue you are describing.
Disable it and you will be good to go [thumbsup2]
Ok,
So I entered in the No User Source Number (Shown Above) and took the Master out of provisioning. Then I changed the NTP setting to CST while it was out of provisioning and put the Master back into provisioning mode.
This has fixed the time issue and the No User entry has fixed the Frequency...
I haven't tried this yet, However this is what Avaya has sent me to correct the issue. I will re-post if this fixes the issue so you can keep provisioning on.
Under the No User Profile
Go to Source Numbers and enter this
ipbs_fr_na
It's supposed to keep the Master from changing back to Europe.
So I have had this issue recently and just wanted to see if anyone else has encountered this issue.
IP Office 8.0.44
DECT Master W/13 Slaves (Not Compacts)
Voice mail Pro is the time server
Running Provisioning Mode
Frequency Issue
When rebooting the master base station the frequency of the...
Hopefully someone has had this issue before because it is driving me nuts.
Here is the Scenario
Inbound call to DID pointed to an extension. That Extension is Call Forwarded Off-Premise to a Long Distance Number, I get the NEC Prompt that say (Please Hold your call is being transferred)Then the...