Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations SkipVought on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Poejay79

    hi please i need a technical help

    You need to create an icd group with your members and then forward your users to this group on busy no answer, Crested a ps station eg 400 with passcode 1234 Then forward to 591(standard number) Then record fm by dialling *47 400 1234 381 record freeing then press auto dial store key. In...
  2. Poejay79

    Aastra 430 Auto Attendant issue

    Dial *9131# from the phone and record new greeting after tone stops. Also check on voicemail tab if record after global greeting is set to yes
  3. Poejay79

    SIP in TDE 200

    You don't need 8.1 you need to make sure you have a VoIP card installed with sip extensions it and then configure virtual car as sip-ext under slots You should then be able to create a user and password for the yealink
  4. Poejay79

    Polycom 6000 on Mitel 5000cp - ver 3.1.2.18

    You need to upgrade he system, as you need cat f licenses for this to work. Has to be 4.0 or above
  5. Poejay79

    Mitel 5000 6.1 have to dial slowly to complete call

    You need to change the inter digit timers under system> timers and limits It's set as standard at 15 seconds
  6. Poejay79

    How configure Polycom SoundStation IP 7000 with MiVoice Business

    On the mcd create a new user, standard sip, give username and passcode On polycom, login to webpage of phone via IP address, password is 456 by default In sip You enter IP address of controller and set to dns and udp Under lines add the username and password configured. If you need a screen...

Part and Inventory Search

Back
Top