  1. naltalite

    SACOS needed - LOG display in 3230

    This once happend to me. That time LIM 1 was hanging in periodic dump. If DUBDP; gives you the answer CONGESTION and FIOFP:NODE=SYSN; shows no open files that might be the case. Try RFPUI:LIM=1,UNIT=BUP; best naltalite
  2. naltalite

    Nodes in down state and no alarms in NNM

    If you do unmanage/manage on the nodes in alarm. You should be getting "node down"´s in the alarm log. Otherwise these events might be set to log only in the event configuration.
  3. naltalite

    Command handler for BL commands

    Not as I know of but there is som explanatory text in Alex regarding what function the different program units have. It´s not so hard to figure out what program is doing wrong and needs to be restarted. In ALEX: checkout "Application System [your country] -> Parameter Description ->...
  4. naltalite

    Conference Beep-tone on MD110

    Depends on which Application system and BC release you are using. In the swedish Application system you can turn it off whith ASPAC:PARNUM=166,PARVAL=1; (BC10)
  5. naltalite

    TLU76 interworking with CISCO router

    Should not be a problem. MD110 in BC9 is capable of doing ISDN "Network side".
  6. naltalite

    External follow me problem

    Check if the incoming line is allowed to connect to the outgoing. TCMAP:CON=T;