Running Exchange Serve 2003 on a Windows Server 2003 machine.
We have set a Global Size Limit on Send and Receive at 15 MB, but some users, like myself, need to send larger files, up to 30 MB in size.
So I make sure the Virtual SMTP Server is set to allow sent messages up to 30 MB and in ADUC...
Nevermind, I found it. Went to Terminals&Sets, then to my DN/Set, Line access, Then Line Assignment set 151 to UNASSIGNED and 156 to Appr&Ring.
Done. Back to normal.
Okay, my DiD is LINE 156, currently LINE 151 is coming in on my Direct Line input.
I need to change the input on my incoming line from LINE 151 to LINE 156.
I am not sure how exactly to do that. Also, once I check the target line, will I need to set the target line. Any instructions would be much apreciated.
Thanks.
Whoops, spoke too soon...
I am "mostly" back. The final programming issue I have is that my DiD no longer points to my extension.
My DiD on our PRI points to my extension, but it must have been port related because now when I call my DiD from outside I get a "Call can not be completed as...
Thank you all! I am back to normal and I learned a lot more about programming than I previously knew; I knew some basics but was scared I might mess up the system if I attempted to do too much more without help.
Your expertise and guidance was invaluable and much appreciated!
Okay, so I can tell you that change DN did not retain programming, can I copy the programming of another phone set/DN that has the same incoming lines and access that I need? If so, can someone briefly explain how to do it?
Thanks Serge... I think I'm almost there!
My current Port/DN is:
Port 0108
DN 222
Device is 7310
So now all I need to do is change the DN from the assigned DN to my old DN.
Will this return the programming to my phone set, including all programmed buttons and incoming lines or will they need...
Thanks for the great info guys, I'm learning a lot.
First, when I push "DEVICE" it says "NONE."
Now, here's a little clarification on how I think this happened and the current state of things:
I am still at my old jack/station. I was only using my phone set to test, one-by-one, new jacks...
Okay, so I found my port/DN. It is:
PORT = P0308
DN = 205
What should I do next? Across the bottom of the display it says:
DEVICE >B2 STATE
and they seem to correlate with the three buttons below the display, should I select one of those?
At our office we have a Nortel MICS system and we move personnel around from office-to-office, so Auto-set relocation makes sense for us
Recently, while testing some new phone jacks, my M7310 phone set lost it's Auto-set relocation information.
I have been told that the best way to reconnect...
I was testing new workstations by using my handset (M7310) which had the Follow-Me function enabled. I would plug-in, make sure that the line was active and that my handset information loaded correctly, however, the third time I plugged into a new workstation, my phone lost its programming and...
We have a Norstar MICS system. We had a 0x16 expansion module installed to give us 16 additional extensions. The expansion module is connected to our main system and the wires from the module connect to a punch block - I can not figure out which pair(s) on the punch block we should use to add...
First off, let me say we have made no changes to our Exchange server whatsoever.
We use a Public Folder/Calendar to schedule tasks and the schedule does change constantly. Some of our users access via Outlook and others, who don't have a permanent workstation, access via OWA.
For five (5)...
We are on a PRI with Nortel MICS. One of our DiD's is giving a fast busy signal when called from the outside. The DiD is only set to ring on one set. It was working fine until yesterday, as far as we can tell.
Another interesting thing to note, when we attempt to call that DiD from inside...
We're on a PRI through a NORSTAR MICS system. One of our users has been receiving an “all circuits are busy now, please try your call later” error when attempting to dial out.
Our service provider, cBeyond, said they suspect that when we converted to PRI, these direct lines were not setup...