Hi all,
i've already enquiry the forum but without any result. I'll try again. I'm managing a MD110 BC13 with 16 LIMs and i'm expecting faults since few weeks. Here's what happens:
<EXTEE:DIR=2875;EXTEE:DIR=2875;
SURE? (YES/NO)
<YWAIT
WAIT
WAIT
WAIT
FAULT INTERRUPT
MESSAGE FROM OPERATING...
...005, LAST HIREI: 07:57:01 10OCT18
TIME DATE ERROR CODE
08:32:55 10OCT18 H'18
ADDRESSED UNIT NOT LOADED
ENTER
SWSW B-LEVEL SIGNAL *************** (H'005C)
FROM OCM (H'017) EXE A IN LIM 001
TO ****** (H'002) EXE A IN LIM 005
NUMBER OF DATA BYTES IN SIGNAL = 4...
Hi all,
i'm expecting strange behaviour of my BC13 MD110 system. When i did an EXTEE of any extensions, i got:
<EXTEE:DIR=xxx;
SURE? (YES/NO)
<YWAIT
WAIT
WAIT
WAIT
FAULT INTERRUPT
MESSAGE FROM OPERATING SYSTEM:
RELOAD REQUESTED
RELOAD REQUESTED
SYSTEM INITIATED DATA
<
Sporadically i got...
...16
PU-NO PU-NAME PRODUCT NUMBER REV PATCH
END
then blocking LIM 16:
<BLLTI:LIM=16;BLLTI:LIM=16;
SURE? (YES/NO)
<Y ****** WARNING ******
LIM IS NOW BLOCKED BUT THERE MAY BE EXISTING TRAFFIC
EXECUTED
and then remove from ecosystem...
Hi all,
on an MD110 BC11SP13 i need to configure a short number (1555) that redirect to an external destination (geographic number). So, calls 1555 should be redirected to xxxx.xxxxxxx.
Any hint how to do this ?
Thanks, MP
--
BLOG @ www.zerozone.it
...ACTIVATED NOT SIGNALLING NO CLOCK CONTROL
SIDE 0 ALARM 0010 0000 0000 0001 GSMINPUT 11111110
ERROR RATE LIM TO GS SIDE 0 = 5*10EE-5
ERROR RATE GS TO LIM SIDE 0 = 5*10EE-5
SIDE 0 CONFIG: GJU_G WITH INCORRECTLY CONNECTED GJU_D LINK
Maybe i did some...
...have some external destination connected to a VoIP system through ISDN trunk. DID was 4 digits for all. When internal calls occours, all works fine *but* when there are incoming calls to some external destinations, DID was sent fully and not "chopped to last 4 digits. This occours only for...
...i got a class 4 error:
CLASS: 4
101 FAULTY CLOCK PROCESSOR
DATE TIME ALP NOIF EQU INF1
26FEB18 12:10:20 1 1 002-0-**-** 1
following Alex, i checl LSU and then i want to the PBX to check LSU board. The only spare part i have is a R11 (installed, and maybe...
Hi all,
i need to change number (at the moment is 2290) to the following phone:
<SUDIP:DIR=2290;DIRECTORY INFORMATION AT 10:42:29 15DEC17
DIRECTORY NUMBER : 2290
TYPE OF DIRECTORY NUMBER : DTS
EXTENSION TERMINAL DATA
EQU TERMD ADN CALALT
2-1-62-14 0021 1...
After further checks, while trying to get CDR via FTP, i got:
* Connected to xxxxx port 21 (#0)
< 220 172.16.41.187 pSOSystem FTP server (NTL68K/1.0.4) ready.
> USER xxxx
< 331 Password required for xxxx
> PASS xx
< 230 User xxx logged in.
> PWD
< 550 4.0/
> PASV
* Connect data stream passively...
Thanks for your kindly help. But i've not REU nor RG5DC in this lim. Maybe the PU4DC ? And can i replace the PUA4DC with a RG5DC ?
Michele
--
BLOG @ www.zerozone.it
...REL 13:
CLASS: 4
102 POWER FAILURE DETECTED BY DSU
DATE TIME ALP NOIF EQU INF1 INF2
25AUG17 08:31:45 1 1 005-0-**-** 0 4
Looking on further posts, i've tried removing all TLU29 boards *but* alarm still there. At the moment, on the LIM there are PU4DC...
...278 CIL DATA LOST FOR ONE OR MORE OUTPUT UNITS
DATE TIME ALP NOIF UNIT EQU INF1
24AUG17 10:35:42 3 1 CLOP 004-*-**-** 2
278 CIL DATA LOST FOR ONE OR MORE OUTPUT UNITS
DATE TIME ALP NOIF UNIT EQU INF1
24AUG17 10:36:17 5 1...
Thanks for your prompt reply. Following flow diagram, seems to be nothing dangerous. So, i clear errors log and waiting for another (hoping no) error. Luckly, there's no ext linked to that LIM.
Michele
--
BLOG @ www.zerozone.it
...07:35:12 06MAR17 H'41
INTER LIM SIGNAL LOST - MISMATCHING SEQUENCE NUMBER
BRANCHVALUE = 00005EFF
ENTER
SWSW B-LEVEL SIGNAL *************** (H'0000)
FROM ****** (H'000) EXE A IN LIM 013
TO ****** (H'000) EXE A IN LIM 003
NO DATA IN SIGNAL
TIME DATE...
...SOFT PARITY ERROR IN LIM PROCESSOR MEMORY.
DATE TIME ALP NOIF UNIT EQU INF1 INF2
03MAR17 11:54:17 3 1 RMP 003-0-**-** 0 0
RDATE RTIME
03MAR17 11:54:17
What it means ? And what i can do ?