  1. jagrasmick

    T1 PRI 100D issue

    Finally found the problem. The CO programming was set to National and not custom. The person that found this difference was Jason (720)480-0305 below are his notes on setup. PRI SETUP ON LEGEND/MAGIX Set Frame Format to Extended Super Frame-Lines/trunks?LS/GS/DS1?’Enter Slot’+ Enter?Frame...
  2. jagrasmick

    T1 PRI 100D issue

    I am receiving errors 7001 on all ports of the T1 card. When dialing from outside to a DID number the recording is all circuits are busy. From inside to outside dialing it is a fast busy. I'll have qwest check the B and D channels. I just double checked 832 is not part of the pool. On either...
  3. jagrasmick

    T1 PRI 100D issue

    Almost forgot to add that I am located in Colorado Springs
  4. jagrasmick

    T1 PRI 100D issue

    DS1 INFORMATION DS1 SLOT ATTRIBUTES Slot Type Format Supp Signal LineComp 4 PRI ESF B8ZS DMI-MOS 1 ----------------------------------- ANNOTATION ----------------------------------- PRI INFORMATION Slot 4 Switch: 5ESS System: By...
  5. jagrasmick

    T1 PRI 100D issue

    Approx 2 years ago we moved from a plain T1 to PRI utilizing 100D board. I have been backing up the system and the other day I had to reboot the system and now the T1 won't work either in or outbound. A tech brought in a new switch matched the settings and still won't work. Qwest (local...