I've got an alarm on a 3300.
DSP Status Minor (although system says major alarm) Total=6 Unavailable = 33%.
Show Status DSP =
Slot Number 6 Dsp 0 State: ACTIVE
Slot Number 6 Dsp 1 State: ACTIVE
Slot Number 6 Dsp 2 State: ACTIVE
Slot Number 6 Dsp 3 State: ACTIVE
Using a Dual Framer so no DSP...
To clarify mark, apart from COS option enabled for hot desking. You must have network ip activate in license form to be able to set cluster element id and ICP/PBX assigned added with local IP address?"
That is correct. Although this was already in the licensing and the ICP/PBX config was...
Hi, I just got it working by changing the "Hot desk login accept" to "Yes" in the class of service for the hot desk user... Can now login fine.
Hope this helps jakt99? Cheers - Mark
Hi, i'm having exact same issue with a teleworker set today. If I create a 'hotdesking' key on the 5330 T/W set (which is up and working) it comes back "not allowed". The Ip address of the 3300 is already in the icp/pbx assignment form.
Any other ideas?
Cheers - Mark