Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Chris Miller on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. DJensen99

    Call Recording and "Dynamic Trunks" (PRI)

    Ah ha - I was wondering if that would work. Time to create 69 b-channel groups. And then I can tweak the trunk usage order as well... Thanks! Valuable information!
  2. DJensen99

    Music on Hold - Do you really need the coupler?

    Seen it done before, worked just fine. I think it's the center pair that's used.
  3. DJensen99

    Call Recording and "Dynamic Trunks" (PRI)

    This is a question I think I already know the answer to, yet I need to relate this information to a vendor. We have just installed a call recording system with our Legend (CKE4 upgraded to Magix 3.0). 3 PRIs, all one pool, trunks 809 to 880 (including D channels), the PRIs are being tapped and...
  4. DJensen99

    400 gs/ls/ttr, Magix and WinSPM

    It does seem to have fixed the "No TTRs" issue, but I traded that issue for the WinSPM issue.... I'll take a peek for 800 DIDs - Thanks!
  5. DJensen99

    400 gs/ls/ttr, Magix and WinSPM

    CKE5 proc 9x 408GS/LS 2x 100DCD 1x 012RG 1x MLM007 4-port 1x 400 gs/ls/ttr Once we increased the load on the system to 50 full-time personnel, we're not quite trunk-tied yet, but we do get "no TTRs available" error messages fairly often. The 400 gs/ls/ttr was meant to fix that.
  6. DJensen99

    400 gs/ls/ttr, Magix and WinSPM

    I enjoy using WinSPM (especially) for labeling, the ease of viewing the restriction lists, and the inventory reports. I suppose it's just a shame that the cards "work, but don't work." Any other cards I can add to this system for a few extra TTRs that won't interfere with WinSPM?
  7. DJensen99

    400 gs/ls/ttr, Magix and WinSPM

    Hello. I've recently installed a used 400 gs/ls/ttr module into slot 14 of our Legend (upgraded to Magix 3.0 v7.0) system. I have verified that the part number of the board (517D18) is compatible with the Magix software. I have gone to Slot Status and observed no errors, and when busying out...
  8. DJensen99

    ARS Local Exchange issue

    Sounds like my best bet is to remap 1-713-555-1212 to the new number and have the local provider block Directory Assistance as well! Thanks all for the help!
  9. DJensen99

    ARS Local Exchange issue

    My understanding is that the "9" (ARS Access Code) should trigger using the ARS tables. At least, that's what the WinSPM documentation states.
  10. DJensen99

    ARS Local Exchange issue

    Merlin Legend 7.0, hybrid mode, programming with WinSPM v9. Trying to get all local calls to the 555 exchange to get remapped to another provider's DA service. We're having the LD provider block access to the 555 exchange on their end. ARS tables (based for Houston TX) : 1] 6-digit 713, 555...