Just to let everyone know, I've just had an opportunity to do an INI of the switch as there's virtually nobody in at the moment and this has resolve the issue. I am not getting any more AUD313 errors reported and I can remotely program the switch again using the OTM GUI.
Many thanks for...
I'll certainly request we get access to LD32 on this other switch when we get the software upgraded as it would have allowed me to sort the problem out myself.
Thanks for your comments and assistance in trying to resolve this issue.
Regards,
Peter
I would have been trying to copy a type 2616 to TN 10 15 as we do not have ACD on this site. However, the comment about the TN possibly being disabled may have caused the corruption in the first place when trying to copy. The only problem is that I don't have access to LD 32 on this system to...
Apologies, in response to the Meridian Mail question, we do not have this on the affected system. We have a standard digital loop card in slot 10 as all TNs on this are in use except 15 which appears to be the one causing the problems.
I only currently have 2nd level password access on this...
Done a bit more digging and found using LD 83 with TNB, shows the problem TN as having a type of 2317 which is certainly not one of our normal types and don't know how that got there but tried OUTing using LD11 and now get a SCH4516 response - M2317 set requires DLT2 package (91).
So getting...
The Option 11 switch is currently running on Release 25 but we are due to get an upgrade soon as we need to expand this system to support additional telephones but just wanted to see if there was a way I can get rid of this error in the meantime.
I appreciate your replies so far and if there is...
Thanks for your replies and the answers are as follows:
LD 32 doesn't work on this system although it does on the other system we have as I get an OVL309 (you do not have access to that overlay) error returned.
With LD 20, I get a SCH0807 (TN is valid but unable to match type) response when...
I have recently been getting regular AUD313 errors reported and the following are a few examples:
AUD313 00001504 DIAL 00000000 00184C5A 000008CB 00000002
AUD313 000000CC DIAL 00000000 00184C5A 000008CB 00000002
AUD313 0000140E DIAL 00000000 00184C5A 000008CB 00000002
I have read through...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.