Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations IamaSherpa on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. cuecuito

    How to configure DIUN2 with DIUC

    Hi everyone Does anybody know the TACSU parameters to configure out DTMF CAS trunks by linkin a Hi Path 4000 (DIUN2) and a Hi Com (DIUC). At least DEVTYPE parameter might be useful. Thank you everybody
  2. cuecuito

    Enable board HUBC

    Does anybody knows how to do it?
  3. cuecuito

    How to configure digital trunks?

    Thank you. By the way, do you know how to install an HUBC card into a V1 Hi Path?
  4. cuecuito

    How to configure digital trunks?

    ISDN,E1 with Qsig signaling.
  5. cuecuito

    How to configure digital trunks?

    Trunks between Hi Path 4000
  6. cuecuito

    Enable board HUBC

    Hi!! I would like to install and enable a HUBC card in a Hi Path 4000 V1 PBX. How can I enable it?? Which slot is best suggested?? Do I need certain AMOs to do it?? I have seen this card allocated next to the DSCXL module. What are the main requirements needed to install HUBC?? I shall...
  7. cuecuito

    How to configure digital trunks?

    I am so sorry, yes you were right, I was looking for TDCSU configuration
  8. cuecuito

    How to configure digital trunks?

    Hi, How could I configure digital trunks with TSCSU? COP & COT parameters remain the same as analog TASCU as well? Thanks
  9. cuecuito

    E1 with CAS trunks trouble

    Hi, I need someone’s help or support. I have configured E1 by CAS trunks through DTMF (DIUN2 Card). COT & COT are well defined but adding NTON parameter in order to avoid hearing next hop PBX tones. However, long periods when calling are noticed if several hops are given until final...
  10. cuecuito

    E1 TRUNKS SOLVED SLOWLY BETWEEN SEVERAL HI PATH

    Hi, I need someone’s help or support. I have configured E1 by CAS trunks through DTMF (DIUN2 Card). COT & COT are well defined but adding NTON parameter in order to avoid hearing next hop PBX tones. However, long periods when calling are noticed if several hops are given until final...
  11. cuecuito

    Hi Path 4000 V1.0 boot trouble

    [thumbsdown]
  12. cuecuito

    Hi Path 4000 V1.0 boot trouble

    I’ll try and then after results I will tell if it worked out. Regards :)
  13. cuecuito

    Hi Path 4000 V1.0 boot trouble

    Thank you Moriendi. I assume the CF (Hi Path 4000 V4) is empty, because the PBX had no inicial configuration but only Dongle values, BCSU equipment including all CSPi modules. I am going to do what you adviced based on STA-INIT AMO command. By the way, an error was shown when I typed COPY-DDS...
  14. cuecuito

    Hi Path 4000 V1.0 boot trouble

    Oh I appreciate you took time to reply my post. I am going to apply your advices and procedure. Then only thing I do not certainly know is whether the CF is blank or empty in order to DEACT with DSSM. The CF was added by Siemens when the enterprise bought the Hi Path 4000 but has never been...
  15. cuecuito

    Hi Path 4000 V1.0 boot trouble

    How can I save a copy from HD to MO in V1 and flash card in V4? Using DDSRM? Thank you
  16. cuecuito

    Hi Path 4000 V1.0 boot trouble

    Hi. I have resolved this issue. I asked a friend to share the latest backups from general REGEN by VEGAS, etc, etc. I realised that the DONGLE codewords were different between 2006 backup and 2007. How could it be possible if no Siemens support was given at that time? ADD-CODEW: (new code)...
  17. cuecuito

    Hi Path 4000 V1.0 boot trouble

    Thanks a lot. I have thought the HD is damaged or corrupt as you said because displays goes to 0 to 6 on and on. I isolated the HD and booted from MO. All cards in LTU turned OK and Q2270-X turned A. This means that MO works fine. Unfortunately, when I want to display configuration, there is an...
  18. cuecuito

    Hi Path 4000 V1.0 boot trouble

    Help, I had a trouble: a Hi Path 4000 had to be turned off for changing its position into the telecommunications site. When it was connected to power supply again, system could not be booted. Display got boot process until number 6, and again 0...6. So, I used a MO disk that initially was...