Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations IamaSherpa on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. LeanClink

    Dynamic Print Directives

    Hi Cathal, I am working with Micros RES 3700. Edit: grammar
  2. LeanClink

    Dynamic Print Directives

    Is it possible to use format in order to embed print directives dynamically? For example, I want to parse the following string: HELLO {B}WORLD{/B}{=24} If using printline, it would be like this: printline "HELLO", @Redon, "WORLD" {>(24)} Is it possible to use format or a different...
  3. LeanClink

    Micros 3700 SIM Substring command

    Thanks Cathal! That works. Thanks for always helping out on this sub!
  4. LeanClink

    Micros 3700 SIM Substring command

    Hello all, Is there a substring function in Micros 3700 SIM? For example, pseudocode below: var str : A20 = "LongString" var str1:A10 = substring(str,1,4) //will output "Long" var str2:A10 = substring(str,5,10) //will output "String" I tried to look in documentation but cannot find anything...
  5. LeanClink

    @DTL_Selected always returns 0 for doing a "Void"

    I am trying out event tmed and @DTL variables. What I want to do is, select a Tender and identify if the action done is "VOID". However, for some reason, @DTL_SELECTED is always 0 even if the Tender has been selected. Is there anything wrong with what I am doing below? [ol 1] Select a Partial...
  6. LeanClink

    LoadKybdmacro not working

    Thanks Cathal! That worked perfectly!
  7. LeanClink

    LoadKybdmacro not working

    Yes, to be specific, it is the number in "Interfaces" in POS Configurator. I am not sure where I can find interface_def table? Table view shows the same number.
  8. LeanClink

    LoadKybdmacro not working

    I am trying to use LoadKybdmacro command but for some reason it is throwing "ISL Error No SIM File". I am pretty sure I specified the correct details. I am trying to call Event Inq 18, and the interface has the ID of 5. I already tried reloading DB but same error happens. Am I doing something...
  9. LeanClink

    Interface Not Active but service is accessible using telnet

    Thank you Cathal! I'm pretty new to this so didn't realize you needed to reload DB after Interface configuration. I was just restarting it since ISL file changes seemed to reflect. It is proceeding now :)
  10. LeanClink

    Interface Not Active but service is accessible using telnet

    We have developed a local TCP service for testing; it is simple service that echoes string sent to it and appends ' -received' Service is hosted on same server and using port 5009. Using telnet, it works properly. However, using below code, it errors on rxmsg, specifically showing "Interface...

Part and Inventory Search

Back
Top