Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. vgenrikh

    SV9500 - Incoming calls with blocked-caller-ID get Name Display "TIE"

    When an external/inbound call is received from a caller who has blocked their caller ID, the station displays "TIE", as if the call was routing through IP CCIS. This is not the case for any other incoming calls, whether local, long distance or international, as long as there is a caller ID, all...
  2. vgenrikh

    SV9500 - Grandstream HT812/814 Paging

    Thank you guys for your replies. Yeah, I looked at Valcom and Viking page adapters and seem to be what I need to have. Thanks again.
  3. vgenrikh

    SV9500 - Grandstream HT812/814 Paging

    The way I had it set up is that, HT812 was configured to communicate with the phone server. The PBX was programmed to have a number for the HT812 in AISTL and then AKYD primary line was assigned. Then from HT812 I ran RJ 11. One end was cut other one was plugged in to the HT812 FXS port 1. The...
  4. vgenrikh

    SV9500 - Grandstream HT812/814 Paging

    Yes, I can. The analog phone works totally fine. I discovered that in my case since I have IP PBX I will need an additional module to make that happen. Bogen TAMB2 in this case. But if you have any other suggestions to make it work without it, I'm willing to check them.
  5. vgenrikh

    SV9500 - Grandstream HT812/814 Paging

    I got Grandstream HT812/814 hoping to set it up to use as an intercom or public announcement with my phone system. The ATA is registered and I'm trying to create one way audio so that you can just call it and have a speech path through the AMP that has TEL input. Is there any other setting in...
  6. vgenrikh

    NEC SV9500 Ringer Mute feature

    Thank you for your answer. I did that (unplugged it and plugged it back) and that didn't do anything. I found that the phone I was testing with was assigned as 24 Line in ADKS and I changed that to 16 Line but that didn't help either. Don't know if it has something to do that it is 6 button...
  7. vgenrikh

    NEC SV9500 Ringer Mute feature

    Ringer Mute feature was needed on few of the phones. ADSL is programmed SN=0 and FKY =117 and the feature can be seen on the displays. When tried to activate it says "ringer off" but the incoming call still have sound. Phones are ITL-6DE. Any idea what else I need to check?

Part and Inventory Search

Back
Top