Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: NoUa
  • Order by date
  1. NoUa

    AODN number does not hunt on station keys

    Sorry, Fix was programing MCR's on sta that answers calls after hours. Thanks again
  2. NoUa

    AODN number does not hunt on station keys

    Hi All, Thanks to every one for your input, trouble resolved. Thank you, John.
  3. NoUa

    AODN number does not hunt on station keys

    Hi, A little more information. When a call comes in on prime DN 5555 (AODN from attendent) customer reports that the next caller hears ringing but no ones picks up. Front desk clerk reports that second line doesn't flash or ring, so it seems like the station is not hunting correctly. This...
  4. NoUa

    AODN number does not hunt on station keys

    Sorry, here it is again. DES 3904 TN 07 0 00 00 TYPE 3904 CDEN 8D CUST 0 KBA 1 FDN TGAR 1 LDN NO NCOS 4 SGRP 0 RNPG 0 SCI 0 SSU 0000 LNRS 16 XLST CLS CTD FBD WTA LPR MTD FNA HTA ADD HFA GRLA CRPA STSD MWA LMPN RMMD SMWD AAD IMD XHD IRD NID OLD VCE DRG1 POD DSX VMD CMSD SLKD...
  5. NoUa

    AODN number does not hunt on station keys

    Hi EddieDuece, Here is the information that you requested. TYPE ATT_DATA CUST 00 OPT AHD BBIN BIXA BLA DNX IC1 ITG IDP XLF XBL FKA MWUD LOA REA SYA ATDA ATDN 0 NCOS 5 CWUP YES CWCL 1 2 CWTM 2 8 CWBZ YES YES EFLL 0 MATT NO RTIM 30 30 30 ATIM 0 AQTT 30 AODN 5555 SPVC 00 SBLF NO...
  6. NoUa

    AODN number does not hunt on station keys

    I having trouble with a AODN that forwards on busy to a STA DN but, on the next incoming call it does not hunt up the keys on that station. Customer reports number just rings and rings but no answer. Does any one have an idea as how to resolve this. Thanks
  7. NoUa

    Error BUG6071

    Continous print-out of this error, Nortel recommends a patch but this switch does not have digital trunking. Does any one else have an idea what might be causing this error? "BUG6071 Invalid CR pointer 0x17. CR range is (0x320dff, 0x34d27c)
  8. NoUa

    ERR5306 Need help breaking down HEX code to determine cause of error

    Need help in breaking down HEX code to determine where error is propagating from. Error reads: ERR5306 0000401F 00004F2 Any help is appreciated. Thanks in advance, Cliff

Part and Inventory Search

Back
Top