  1. sfurley

    SIP devices on Mitel 3300.

    Thanks, i'll give it a try on Monday.
  2. sfurley

    SIP devices on Mitel 3300.

    Thank you. I'm home now. I can look at the Mitel system remotely, but the 'phone is not plugged in at the moment, so I'll have to leave it until Monday. I did read that thread before, but I'm still somewhat confused by the term 'SIP account'. Under 'Multiline IP Sets' I've added a new...
  3. sfurley

    SIP devices on Mitel 3300.

    We have a mitel 3300 MXe controller with Release Level 5.0 SP2 PR2. At present we have mainly Mitel 5001, 5201, 5212 and 5304 IP handsets, plus a few other odd Mitel models, and about 80 remaining analogue ones, fax machines etc. We are investigating the possibility of using a few non-mitel...
  4. sfurley

    Stacking Error On Summit x250-e

    If nothing that dphoneguy24 or myself have suggested helps send us the output from 'show stacking', 'show stacking configuration' and 'show switch'; there may be something there that we can pick up. Stephen.
  5. sfurley

    Stacking Error On Summit x250-e

    Have you connected the stacking ports correctly? Port 1 on one switch should go to port 2 on the other. You mention 'a stacking cable'; do you only have one stacking cable connected? You should really have two cables connected, so the switches are in a ring, but it should still work with only...
  6. sfurley

    How to route Extreme over Cisco Network

    If the above is the problem then the command you need is: configure iproute add default <ip address>
  7. sfurley

    QoS on Summitstack.

    The Extreme XOS Concepts Guide states that Qosprofile QP7 cannot be created on stacked switches, but I have read somewhere, I can't remember where, that both QP7 and QP6 are unavailable when switches are stacked; which is correct plese? We used to use QP7 for IP telephony, but re-configured...
  8. sfurley

    100 Base-FX SFP modules.

    I needed four of these modules and all are now working correctly, but I had to use a different version(10063)on the DB 8810 and Summit x450a 24x to the one which works on the Summit x250e 48p (10067). The 10063 is both longer and more expensive. Presumably the optics are going to be the same...