Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations Mike Lewis on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. wayne079

    Ns700 auto attendant issue

    Hi OBT, You got it.......What confused me was the recall timer in the UM settings. I thought this must be a new addition compared to the seperate The manual under the setting for the UM describes setting this timeout longer than the timeout for Intercept destinations at the pbx or the pbx...
  2. wayne079

    Ns700 auto attendant issue

    Sorry I should say that's using a custom service on the in built UM.
  3. wayne079

    Ns700 auto attendant issue

    Hi OBT, As its an NS700 I'm using the in built UM. I've already got FXD configured in the UM Config - System Parameters - Parameters for the operator transfer sequence, the extension transfer sequence and the alternate extension transfer sequence. In the Dialling Parameters/MSW Notification...
  4. wayne079

    Ns700 auto attendant issue

    Any help or assistance greatly received. I've recently installed an Ns700 which had auto attendant option 1,1 pointed at ICD group 622. After callers select this option and with queuing and busy both set to none, callers revert to the top level of aa and the menu repeating after just over a...
  5. wayne079

    Addressable fire alarm system and interference to data network.

    Cable used is Vencroft low burn, with 1mm conductors a foiled screen and tinned annealed copper CPC (Earth). In the places where the most interference is caused, there appears to be 4 cables running parelell. So we should be asking if ground tests have been done? The manafacturer (different...
  6. wayne079

    Addressable fire alarm system and interference to data network.

    Current network is cat6. They are aware and have installed to the correct British standard. As such they are unwilling....They are using screened cable but I've never seen interference of this magnitude. They say the screening on the cable is there to prevent induction into their circuit. In...
  7. wayne079

    Addressable fire alarm system and interference to data network.

    We are talking about an 80 bed hotel here. It is coming from the fire system and this has been proved.
  8. wayne079

    Addressable fire alarm system and interference to data network.

    Hi, Wondered if anyone can share an opinion on the following:- My employers have recently had an alarm company install an addressable system inside a hotel. We are having difficulty with the interference from the FP200 rated, screened cable that they have used to install their circuits. I...
  9. wayne079

    KX-TDA100D Version Upgrade Guide

    Of the top of my head, I thought that the 5 series were only compatible from v8 of the maintenance console. When I was provided with the V8 software all of the relevant card upgrades came with it.
  10. wayne079

    Kx-NS1000

    Its a physical card. Legacy Gateway Cards KX-NS0132 Stacking Card for KX-TDE Series (STACK-S (TDE)) Its in the documentation for the NS1000 on page 7 of the installation manual for v3.2
  11. wayne079

    Max Busy Extensions in Incoming Call Distribution Group

    Use a queuing time table under ICD Groups and record the necessary OGM to inform the person queuing that they are in the queue.
  12. wayne079

    Multiple ISDN30 circuits

    Afternoon people, I have a question regarding the setup of multiple ISDN30 circuits on the same switch. ie 2 x PRI30 cards We will be installing a new NS700 system in the building in question but would like to know how this would have been configured in a KXTDA/NCP/NS system. Our current...
  13. wayne079

    TVM200 ICD Group Mailbox

    thanks OBT, I found it eventually. May have been a slight oversight on my part. Cheers
  14. wayne079

    TVM200 ICD Group Mailbox

    Afternoon Gents, I have an issue with a KXTDA200 and TVM200 and Group Voicemail I have an auto attendant system with 6 options forwarding to various ICD Group eg 6605 6611 Im trying to re-record the greeting for the group mailbox by logging into VPS system with 500#6*6605# I gain access to...
  15. wayne079

    some questions about tda 200

    COS Settings under Extension Feature tab??!?! (Call Monitor) The other questions don't make sense.
  16. wayne079

    TDE 100 password

    Google TDE password reminder.
  17. wayne079

    alarm in tda200

    From maintenance console 4.1.4 Flexible Button, drop down the type until you get to system alarm on the extension you require. From the Handset - Program - Flexible button to be assigned - 58 - Auto dial/Store - Program to exit
  18. wayne079

    KXTD1232 DDI's and extension groups.

    This system has already been programmed. This is how it was setup by the past "professional" I can see what you meant though CWC3. I assigned each of the phantom extensions on a flexible button and now they ring as part of the DDI. Thank you for your help, most kind.
  19. wayne079

    KXTD1232 DDI's and extension groups.

    Hi, Im having a problem programming DDI's to extension numbers for certain DDI's. We have three DDI's that are affected. 002 - 373 (373 is a phantom extension which rings at 208 and 209) 003 - 374 (374 is also a phantom extension which rings at 208 and 209) 013 - 208 - This rings direct at...
  20. wayne079

    Phone engineers equipment

    Thanks JRgood I have the following so far, work are paying for all the tools and training to bring all telephony in house, over the next three years. Test set with caller ID (display) - Purchased today http://uk.rs-online.com/web/p/telecom-test-equipment/7659602/ Tone generator and probe -...

Part and Inventory Search

Back
Top