    Limit maximum number of digits

    In the meantime I found the solution myself. In fact I had to increase the maximum number in the aar analysis table. However I did it in the wrong place. I was dialing 8(fac)-9... However I altered the entry starting with 8. I do not work very often with the PBX and forgot that within the aar...
  2. ishujw

    Limit maximum number of digits

    Dear all, we have a Definity ECS. We use 8 as fac for aar. From there we route to trunk 6. We have the problem that after the 8 we can enter maximum 13 digits. However we need 14 or even better 15. When I enter the trunk acces code directly the number of digits seems to be not limited, only...
  3. ishujw

    TN556D with non-Avaya ISDN phone

    Can someone give me a hint? I have a Siemens Profiset 51 ISDN phone and want to add it as a station to a TN556D card. Is this possible? How should I configure? Thanks in advance
  4. ishujw

    No ringback tone through SIP Gateway

    I have set up an ISDN trunk on a TN556D card and connected to a Lancom 1724 VoIP router. I can make calls and also talk with others, but I do not hear a ringback tone (nor other progress tones). Though I can hear a dial tone when entering the TAC directly. For testing purposes I have set up the...