this is not going well, ci remember doing this in the past now that you mention it (the ACD) but now i get SCH0430 invalid DN when i enter the number to forward to. sorry to be such a pain.
Not exactly, i am offsite and the customer never cfw the lines. they were working lines when i changed their dn (didnt want to remove until i was sure it would work) then i used that DN on the new phontom. i am def using Phantoms, they are 156 0 11 0. sorry i cannot pull the TNB at this time but...
ok, now the customer has decided that this is a permenant setup and that the phones need to be removed. i am trying to use phantoms to cfw the lines but everytime my test calls hit the system i get an error message that the line i am calling has been disconected. they are known working lines and...
how quickly i forget, former PBX tech forgets the simplest commands. i have been out of the PBXs for a while and cannot remember how to forward an analog set to an external number. it is a local call.
any help is appreciated!
Thank you, I also have another question to this, this is a dual cabinet option 11 and i have a spare dti/pri card on hand. is it possible for me to build this PRI as a second connection and later remove the tie line or would it be best to convert the tie to what i need, please keep in mind i am...
I am trying to allow the caller id to pass between my opting 11 to a mitel PBX. currently i have a point to point TIE line connecting them. what is the best solution to allow my system to pass the caller id on a 911 call to the Mitel. do i need a pri instead. the option 11 is a remote node...
i am having problems adding new TNs to my OTM 1.2 i have installed new cards into a growing system but cannot build new phones through OTM since it does not show these TNs. i am new to OTM and have no books on it.
thanks all, unfortunatly i went to the site this morning and swapped out the card and found that the spare i had was bad and could not be brought up. NPR0326 no response from card. so i will need to get another spare, the old card came up just fine when i put it back in(though it is still...
I have a DTR card that seem to be floking out. whenever i run a test i will get errors on about 1/2 the ports and i get alot of errors all the time for one port in particular (err070 20 1 13 6) i have a spare card and would like to swap it out. is it as easy as disabling the card and...
Good news, after all this the system is up and running fine with no errors, just an FYI, the E-link was taking on a lot of errors and causing all the problems. ince it was disabled everything started working great, at least for now.