Need to program the ability to go from one DAT to another. For example, If in DAT001, greeting will be "For Payment Info press 1". Caller is then transferred to DAT005. Any help would be appreciated.
Thanks
I'm on necntac.com and that version is not listed for the SV9100. The latest version on the site is v11.00.50. Do you think that version will work. If not, where can I find the latest version? If you know.
Just downloaded the latest version from NEC. 10.50.50 for cp10. When i use WEBPro the software level says A12.10.50. Should I be using a downlevel version of PCPro?
Have a SV9100 with a GCD-CP10 processor. I can connect with WEBPro no problem but need to use PCPro for upgrade to a CP20. When I try to use PCPro I get an error:
"Can't connect because it does not support encryption"
I'm using version 10 of PCPro for a CP10. Any help would be appreciated.
Receptionist needs to go away from desk. Need to know if receptionist can send incoming calls temporarily to another extesion?
The extension number she needs to send incoming calls to could change from day to day. I know I could just program another mode to accomplish this but since the...
Trying to set the SL2100 as the DHCP server. Followed instructions the best I can but ip phone responds with "DHCP server not found".
10-12-01 = 192.168.20.254
10-12-02 = 255.255.255.255
10-12-03 = 192.168.20.1
10-12-09 = 192.168.20.69
10-12-10 = 255.255.255.0
84-26-01 = 192.168.20.70...
Greetings!
SL2100 Digital 12 and 24 button sets.
I've programmed a DND Override button on the receptionist phone x101. Tested with x105 in DND ALL but when I test, call still goes to VM. Tried using the preprogrammed code of 707 and get the same result. Am I using the button incorrectly or am...
My system has been experiencing Watchdog alarms and reboots. Haven't been able to find info on what's causing it. Any help in the right direction to fix issue would be appreciated. I've already swapped proc and cab and it still going on.
OS7200s v4.99
Occasionally when I try to access vm on an MP10a or MP20s the system looks like it's working fine then I get disconnected and have to login again, reboot the system, then after reboot I can access vm. This only happens on embedded vm on the proc. The mgmt white list is good and the vm system...
Thank you Ian. Was able to get it working using feature NPG (network paging). Then mgmt. changed course on me and purchased a Valcom product - VIP 801A. Basically its a paging over eithernet device. Works good. Thanks again!!