Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations dencom on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by michelepin

  1. michelepin

    Cannot delete EL6 extension anymore !

    Thanks to all! I have contacted our support service, as suggested, because seems to be a severe data corruption. MP -- BLOG @ www.zerozone.it
  2. michelepin

    Cannot delete EL6 extension anymore !

    Hi all, i've already enquiry the forum but without any result. I'll try again. I'm managing a MD110 BC13 with 16 LIMs and i'm expecting faults since few weeks. Here's what happens: <EXTEE:DIR=2875;EXTEE:DIR=2875; SURE? (YES/NO) <YWAIT WAIT WAIT WAIT FAULT INTERRUPT MESSAGE FROM OPERATING...
  3. michelepin

    FAULT INTERRUPT

    HIMDP return me some errors: <HIMDP; DIAGNOSTICS FROM OPERATING SYSTEM TIME DATE 09:19:08 10OCT18 DIAGNOSTICS FROM LIM 001, LAST HIREI: 07:56:59 10OCT18 TIME DATE ERROR CODE 08:32:56 10OCT18 H'17 FAULTY INDEX LOGICAL PROGRAM ERROR ADDRESS = 02001620 ENTER SWSW B-LEVEL...
  4. michelepin

    FAULT INTERRUPT

    Hi all, i'm expecting strange behaviour of my BC13 MD110 system. When i did an EXTEE of any extensions, i got: <EXTEE:DIR=xxx; SURE? (YES/NO) <YWAIT WAIT WAIT WAIT FAULT INTERRUPT MESSAGE FROM OPERATING SYSTEM: RELOAD REQUESTED RELOAD REQUESTED SYSTEM INITIATED DATA < Sporadically i got...
  5. michelepin

    Removing a LIM from MD110 BC11 ecosystem... this is the right procedure ?

    Hi all, following some threads and the ALEX i try removing LIM 16 from out MD110 BC11 ecosystem with 16 LIMs. First, checking PU there: <CNPUP:LIM=16,CFUNC=YES; LOADED PROGRAM UNITS IN LIM LIM NUMBER 16 PU-NO PU-NAME PRODUCT NUMBER REV PATCH END then blocking LIM 16...
  6. michelepin

    MD11 alias for esternal destination

    Hi all, on an MD110 BC11SP13 i need to configure a short number (1555) that redirect to an external destination (geographic number). So, calls 1555 should be redirected to xxxx.xxxxxxx. Any hint how to do this ? Thanks, MP -- BLOG @ www.zerozone.it
  7. michelepin

    MD101 BC11SP13 - 101 FAULTY CLOCK PROCESSOR

    Thanks for your kidly help: LSU changed. But now i have some other faults and GJLSP got me a: EQU = 2-1-00-0 GS-MULT 0-3 GS SIDE 0 ACTIVE NOT ACTIVATED NOT SIGNALLING NO CLOCK CONTROL SIDE 0 ALARM 0010 0000 0000 0001 GSMINPUT 11111110 ERROR RATE LIM TO GS...
  8. michelepin

    [SOLVED] DID on external destination

    Just for future reference, i add relevant entries on NUMBER CONVERSION DATA table with NUTRI; -- BLOG @ www.zerozone.it
  9. michelepin

    [SOLVED] DID on external destination

    Hi all, on a BC11SP13 i have some external destination connected to a VoIP system through ISDN trunk. DID was 4 digits for all. When internal calls occours, all works fine *but* when there are incoming calls to some external destinations, DID was sent fully and not "chopped to last 4 digits...
  10. michelepin

    MD101 BC11SP13 - 101 FAULTY CLOCK PROCESSOR

    Hi all, this morning i got a class 4 error: CLASS: 4 101 FAULTY CLOCK PROCESSOR DATE TIME ALP NOIF EQU INF1 26FEB18 12:10:20 1 1 002-0-**-** 1 following Alex, i checl LSU and then i want to the PBX to check LSU board. The only spare part i have is a R11...
  11. michelepin

    [SOLVED] Change EXT on a Digital Ext with ADN

    Thanks, i think i've solved with: KSANE:ADN=11190; KSDNC:DIR=3490,DIROLD=2290; SUDIP:DIR=3490 KSANI:DIR=3490,KEY=23,CAT=5,ADN=11190; SUDIP:DIR=3490; SUDIP:DIR=11190; -- BLOG @ www.zerozone.it
  12. michelepin

    [SOLVED] Change EXT on a Digital Ext with ADN

    Hi all, i need to change number (at the moment is 2290) to the following phone: <SUDIP:DIR=2290;DIRECTORY INFORMATION AT 10:42:29 15DEC17 DIRECTORY NUMBER : 2290 TYPE OF DIRECTORY NUMBER : DTS EXTENSION TERMINAL DATA EQU TERMD ADN CALALT 2-1-62-14 0021 1...
  13. michelepin

    ERROR DURING DUMPING OF CIL DATA

    After further checks, while trying to get CDR via FTP, i got: * Connected to xxxxx port 21 (#0) < 220 172.16.41.187 pSOSystem FTP server (NTL68K/1.0.4) ready. > USER xxxx < 331 Password required for xxxx > PASS xx < 230 User xxx logged in. > PWD < 550 4.0/ > PASV * Connect data stream passively...
  14. michelepin

    102 POWER FAILURE DETECTED BY DSU

    Thanks for your kindly help. But i've not REU nor RG5DC in this lim. Maybe the PU4DC ? And can i replace the PUA4DC with a RG5DC ? Michele -- BLOG @ www.zerozone.it
  15. michelepin

    102 POWER FAILURE DETECTED BY DSU

    Hi all, i've got this error on my MD110 BC11 REL 13: CLASS: 4 102 POWER FAILURE DETECTED BY DSU DATE TIME ALP NOIF EQU INF1 INF2 25AUG17 08:31:45 1 1 005-0-**-** 0 4 Looking on further posts, i've tried removing all TLU29 boards *but* alarm still there...

Part and Inventory Search