Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations strongm on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Recent content by Matty269

  1. Matty269

    restore on Virtual mitel 3300 ISS

    Virtual mitel 3300 rel 7.2 running on an ISS need to backup and restore database due to a corrupt DB is there any special procedure or is it the same as an MCD ICP controller? on an MXEII there needs to be a manual reset after the restore is it the same on a virtual or is the reset done on...
  2. Matty269

    bringing up an old thread have a 33

    update Thanks for all your help guys I used the customer unused 3300 mxeIII controller and moved all the cards and I button over and changed the ARID then sync'd licenses then did a restore from the latest backup system up and running 100% now the old controller on a test bench tried to...
  3. Matty269

    bringing up an old thread have a 33

    update tried replacing drives but I think there may be a problem with the boot string the system was 7.0 and was updated to 8.0 sometime back after clearing sockets the raid sees the drive and starts to boot then says can't load boot file i think the controller is looking for the updated...
  4. Matty269

    bringing up an old thread have a 33

    Billz66 thanks for the info not sure I guess I will just do the drive replacement has listed above and go from there
  5. Matty269

    bringing up an old thread have a 33

    one more question down time is hard to get, I have access to a controller that is the same software level and currently not used it has basic licenses can I used that controller to install a hard drive load the new certificate, then sync to the amc and then restore the database from the...
  6. Matty269

    bringing up an old thread have a 33

    thanks I almost forgot about the updated cert yes I have a twin pack of drives with the same software revision as the original drives so do I have this right 1. connect to maint port with my laptop 2. power down controller and remove both drives 3. power up and watch for socket cleared...
  7. Matty269

    bringing up an old thread have a 33

    bringing up an old thread have a 3300 mxeiii controller running rel 8.0 ver 14.0.93 sata raid recently it just locks up phones loose connection and no access to esm a power off reboot brings it back for a week or two then it happens again Mitel recommends drive replacement in a pair I was...
  8. Matty269

    Can't add extension

    i have to deal with some very old 3300 software and issues like this always seem to be a browser issue pop ups , trusted sites, compatibilty 8.0 is fairly new and i use IE or firefox to make changes even on the old 6.0 i use edge in IE mode and it works ok have you tried another browser
  9. Matty269

    Can't add extension

    yes more info needed like software level and what browser you are using
  10. Matty269

    changing IP addresses in a 2 controller cluster

    kwbmitel Thanks I have done the E2T card on new installs in our lab before they went to the site and did 2 putty sessions one to 2002 and one to 2007 to set the IP for the e2t. tricky if I remember correctly I guess I am a bit leary of the cluster and the SDS and making sure every form that...
  11. Matty269

    changing IP addresses in a 2 controller cluster

    Sorry I was a bit vague 1 MXE controller 1 MXE III controller 12.0.3.15 latest rel 6.0 SP3 the latest supported version that handles Per Nodes with digital phones No DHCP on the controllers it is handled by their network the IP Phones are on the new network IP scheme and hardware but...
  12. Matty269

    changing IP addresses in a 2 controller cluster

    looking for some tips on this. the site has 2 controllers in a cluster they need to change the ip addresses they are moving to a new network. I know the SDS will change some items but not others one controller has an E2T card so that will need to change via the maint. port I was going to change...
  13. Matty269

    older mitel 3300 with digital phones and PER nodes alarms

    Eyes my alarms are not always from the same per node / fim card they rotate around between all the per nodes keep us posted on replacing the fim card
  14. Matty269

    older mitel 3300 with digital phones and PER nodes alarms

    Eyes the connection loss in my case is momentary the cabinet comes right back in like a minute every time but when they were doing an intrusive scan both controllers lost their mind they needed to be reset by the front panel that hasn't happened again this site is a large health care campus...
  15. Matty269

    older mitel 3300 with digital phones and PER nodes alarms

    EYES, I have not resolved this as of yet but I am convinced it is some security device on their network causing this. my reasoning: 1. the alarms are like clock work right after an AMC sync in both controllers at this site when they stopped all network work around the holidays the alarms...