  1. asmonemmtel

    i need the md110 Application Link 4.0

    very thanks parnum Is there a way to send csta command to csta without the Application Link? simulation or module for send csta?
  2. asmonemmtel

    i need the md110 Application Link 4.0

    hello i need the application link 4.0 and search the internet but not found the file. please help me. very thanks.
  3. asmonemmtel

    tda100 trunk call conference

    connecting the rda100 and other pbx systems i need the call conference between the two extensions on the tda100 to other pbx uses the E1 trunk. please help
  4. asmonemmtel

    E1 trunk of kx-tda100 and other pbx

    i config the kx-tda100 for E1 trunk. other system dialing to panasonic extensions but panasonic not dialing to E1 trunk. example: ring ok and start the call other pbx extension 1003 kx-tda100 extension 101 dial 101 ------------------------> E1...
  5. asmonemmtel

    panasonic kx-tda100 phone assistant barge-in not working

    enable all config on the maintenance console/system/cos setting but error barge: failed to barge in to the selected ongoing call.
  6. asmonemmtel

    panasonic kx-tda100 phone assistant barge-in not working

    very tanks obtsystems i not found class of service on extension setting on the maintenance console. please help for find the path of config?
  7. asmonemmtel

    panasonic kx-tda100 phone assistant barge-in not working

    i config the phone assistant client 3rd party to pbx kx-tda100. call event and supervisory is activated. but barge not working and error: failed to barge in to the selected ongoing call. https://www.imageupload.co.uk/images/2015/04/04/failed-barge.png please help very tanks
  8. asmonemmtel

    panasonic phone assistant remember password

    install pa and login error the username and password. please help for remember phone assistant password.
  9. asmonemmtel

    cti not working on tda-100

    yes kx-tda100 and cti-card i ping to tda-100 and enable cti login on the mantance console(port 33333). but login for cti(use the rander) not working. very tanks. please help.
  10. asmonemmtel

    cti not working on tda-100

    i uses the rander for monitor all call of pbx panasonic kx-tda100. tapi services is enabled and network connected. but rander not connect to pbx. please help. very tanks.
  11. asmonemmtel

    kx-tda100 li or record call

    online for call record. if two extension calling and record online voice. very tanks.
  12. asmonemmtel

    kx-tda100 li or record call

    very tanks obtsystems smdr is offline data but my need the online media please help very tanks
  13. asmonemmtel

    kx-tda100 li or record call

    please help
  14. asmonemmtel

    kx-tda100 li or record call

    hello i need the getting event and call media for recording on tda-100. kx-tde dll for programming but tda-100 not used the dll. i need the best solution & command for getting event and call recording. very thanks.
  15. asmonemmtel

    call mirror on elu32

    im network programmer and read the alex library and information about the md110 technology. but not find the best solution for call mirror and record. very tanks the parnum.