I'm assuming you're using a "Cascade" order on the ring group. The only way I know how to is to remove everyone and put them into the order you want.
I've only built a Cascade Ring group one time and it was quickly changed to "ring all" with overflows to other ring groups that add other...
I have seen line cards kill a bay. Pull all the cards from slots 1-8 and power it back on. If the Bay Control comes up, then it's likely one of the line cards. Put them in, one at a time. and see which one kills the bay.
Where are you located?
That's what I thought too. Figured I'd check while trying to fix this old shiva plug probe.
I did get it to work. It just took a while for it to appear as checked in and ready. I repeated the process twice before I noticed it happen.
Has anyone here managed to install the MPA probe blade on a 3300 ICP that is running on a CX-II or MXe-III?
I have a site that has an older Marwatch probe, and of course Martello support has told me to contact Mitel Support. Mitel Support basically said they don't know anything about any such...
I agree... hopefully they come back stronger than before.
As for the merger with intertel, they became difficult to work with Sales and Marketing after the merger.
The impression they gave dealers is that they bought out Intertel as it was a failing company that Mitel wanted some parts of...
Mitel filed Chapter 11 bankruptcy the other day.
I've been working on Mitel systems since 1997 and have noticed a significant change in structure (detriment) in the past few years. The most recent change is migration from AMC to the Licenses and Services hasn't been a good experience.
I have...
Drive is bad or corrupt.
If the system has two drives, pull one of them and power it up. If that didn't resolve it, put it back in and pull the other and try again.
If the system only has one drive, you'll need to rebuild the system.
You'll need the following:
1 - the most recent backup.
2...
I wonder if you'd be able to figure it out from the output from this. I wonder if the 12-digit code is an ASCII code.
https://pbxbook.com/other/mitel/sx200pass.html
The procedure for defaulting the password on an SX200 is as follows:
From maintenance, login with the username of: password
and...
I'm following this. I have worked on Mitel systems since 1997 and I have worked on all flavors of the SX200 from Analog to ICP and have had several systems that we maintain that we only have access to Maint1.
The EL processor cards has a Serial connector near the MOSS chip (without looking, I...
I missed the part that it appeared to be an ARS entry that was failing.
One of the first sites we set up SDS for, they had shared as many forms as possible - including ARS digits dialed (and others). This wreaked havoc on SDS errors for similar issues.
As pointed out, the Route List entry...