I'm learning TKinter slowly and trying to use it for a small home project.
I have a grid filled from a Python list, that is working, but I would like to add a top row with column headings, and force the grid to be centered in the window. I have created grids with manually coded rows, having...
This is a first for me. The customer has been complaining about this phone making ticking sounds. After switching wiring pairs, testing with a new VU9208 phone, and testing the phone at the switch/KSU port, I realized something is odd about the port. The speaker phone will not operate. Testing...
Thanks Curlycord.
I don’t think vm is setup on this station, It does have the common password given at time of installation, but the voicemail doesn't ever pickup when calling this extension.
I'm looking at section 3.10.4 (Station Message Wait/Call Back) of the manual.
Dialing 386:
- Is the...
What might cause Blinking Message & Call Back button LEDs, and pulsing dial tone when there are no messages present in voicemail?
Any advice appreciated.
Thanks curlycord,
Would the software corruption on the port be permanent?
I need to do a system backup and upgrade soon on this system.
I'm going to reprogram the buttons and keep an eye on it.
I'll explain to the customer it is very unusual. She may have tried moving her desk phone to a...
What might cause a VU-9224F 24-button phone to loose it's user's button assignments?
They were all assigned to other user station numbers.
The other VU-9224F phone in the same system has had no problems.
The system is about a year and a half old. I have not seen this happen in other Summit 80...
I can't seem to find this option in the station programming.
I would like to program Hold/Save station buttons to place the CO call on hold, Without giving the intercom dial tone.
Any advice appreciated?
Resolved. (Manual, programming, P. 2-107)
I enabled the Line key 4 for COL access using 'CO Line Selection(Installed, DP, DTMF)LK3, Data No. 10.
Changing the Setting data to: MF restored the LK 4 CO line access.
Thanks Belevedere.
I do have the original 378 page manual (with programming) for this system 'Electra Professional Level 1' 1998.
I have been programming and managing this system for years, just have never added a trunk line. Other NECs like this we serviced over the years had access to at...
I have added a 4th CO line to an old NEC Electra system, and just found out none of the phones (Line 4 button) will actually Select the COL 4.
Additionally, no station rings, and no Line 4 button lights on incoming ringing COL 4.
I have tested the CO line at the modular plug going into the...
Does anyone have any idea why a feature button would flash, the phones user does not use any special features.
I haven;t found this answer in the station user manual yet.
Entering: Feature 69 Feature did not stop the flash.
Any advice appreciated.
I could use a bit of advice on setting up Automated Attendant Delayed Ring Assignment.
I believe this is the correct feature for what I need, to have select station ports ring with CO lines, If ports 01 & 02 fail to answer CO/PBX line rings for > 10 Seconds.
So far I have Programmed:
LK4, Data...
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
By continuing to use this site, you are consenting to our use of cookies.