Try turning off TRO on the RDB the other thing that may be causing your issue is different releases between the two systems. If this is the case there is a patch for the sig server and the call server
I printed this error code on my CS1000E and my CS1000M and got the same Invalid NTP table error. Both of these Call Servers mentioned above are current on their dep lists. My guess is it's a bug Nortel hasn't fixed yet.
My company was in an almost identical situation about five years ago, we had three 81c's with fnf numerous opt11c sites and probably 50 or so Norstar's, we started looking into VOIP and decided to leverage our existing Nortel equipment by IP enabling it, keep in mind we are a Cisco shop as far...
I am being told Nortel has a VOIP Bandwidth Demand calculator, basically a excel spreadsheet designed to help in calculating zone sizes, does anyone have a copy of this or know where we can get it?